Cox I J, Coutts G A, Gadian D G, Ghosh P, Sargentoni J, Young I R
NMR Unit, Hammersmith Hospital, London, United Kingdom.
Magn Reson Med. 1991 Jan;17(1):53-61. doi: 10.1002/mrm.1910170110.
Phosphorus-31 liver spectra were recorded from 6 controls and 12 patients with liver disease using TR values of 0.5 and 5 s and a pulse angle of 45 degrees. One of the control subjects was also examined at seven TR values ranging from 0.5 to 20 s. Spectra from one additional patient were collected at TRs of 0.5, 1, and 2 s only. There was a significant increase in the mean ratio of peak areas phosphomonoesters (PME)/beta-ATP in 9 of the 13 patients and a decrease in phosphodiesters (PDE)/beta-ATP in 3 of the patients, compared with controls, at the longer TR values. The saturation factors for PME and PDE were greater than those for Pi and beta-ATP, and spectral abnormalities in disease were often more evident as the TR value was increased from 0.5 to 5 s. Acquisition parameters need to be chosen with a knowledge of the impact that saturation effects have on metabolite quantification and spectral contrast.
使用0.5秒和5秒的重复时间(TR)以及45度的脉冲角度,对6名对照者和12名肝病患者记录了磷-31肝脏光谱。其中一名对照者还在0.5至20秒的7个TR值下进行了检查。仅在TR值为0.5、1和2秒时收集了另外一名患者的光谱。与对照者相比,在较长TR值时,13名患者中有9名的磷酸单酯(PME)/β-ATP峰面积平均比值显著增加,3名患者的磷酸二酯(PDE)/β-ATP降低。PME和PDE的饱和因子大于无机磷(Pi)和β-ATP的饱和因子,并且随着TR值从0.5秒增加到5秒,疾病中的光谱异常通常更明显。在选择采集参数时,需要了解饱和效应对代谢物定量和光谱对比度的影响。