21个N95过滤式面罩呼吸器长期储存后的过滤性能评估。

Evaluation of the filtration performance of 21 N95 filtering face piece respirators after prolonged storage.

作者信息

Viscusi Dennis J, Bergman Mike, Sinkule Edward, Shaffer Ronald E

机构信息

National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, Pittsburgh, PA.

EG&G Technical Services, Inc, Pittsburgh, PA.

出版信息

Am J Infect Control. 2009 Jun;37(5):381-386. doi: 10.1016/j.ajic.2008.09.021. Epub 2009 Feb 1.

Abstract

BACKGROUND

Organizations are stockpiling respirators to prepare for an influenza pandemic. To understand better the effects of prolonged storage, this investigation evaluated the filtration efficiency of 21 different models of National Institute for Occupational Safety and Health (NIOSH)-certified disposable N95 filtering face piece respirators. These respirators had been stored in their original packaging for a period of at least 6 years in research laboratories and dry warehouse facilities, ranging in temperature between 15 degrees C and 32 degrees C and relative humidity between 20% and 80%.

METHODS

Filter penetration was measured using an abbreviated version of the NIOSH respirator certification test incorporating a polydisperse sodium chloride aerosol at 85 L/min.

RESULTS

Of the 21 respirator models tested, 19 models had both average penetration results of less than 5%. Mean initial penetration values ranged from 0.39% to 5.83%, whereas mean maximum penetration values ranged from 0.95% to 5.83%. There did not appear to be any correlation between the length of storage and failure to pass the filtration test.

CONCLUSION

Results indicate that most N95 filtering face piece respirators stored for up to 10 years at warehouse conditions will likely have expected levels of filtration performance and that the degree of filtration efficiency degradation is likely model specific.

摘要

背景

各机构正在储备呼吸器以应对流感大流行。为了更好地了解长期储存的影响,本研究评估了21种不同型号的美国国家职业安全与健康研究所(NIOSH)认证的一次性N95过滤式面罩呼吸器的过滤效率。这些呼吸器在研究实验室和干燥仓库设施中,原包装储存至少6年,温度在15摄氏度至32摄氏度之间,相对湿度在20%至80%之间。

方法

使用NIOSH呼吸器认证测试的简化版本,在85升/分钟的流量下,采用多分散氯化钠气溶胶测量过滤器穿透率。

结果

在测试的21种呼吸器型号中,19种型号的平均穿透率结果均低于5%。初始平均穿透率值在0.39%至5.83%之间,而最大平均穿透率值在0.95%至5.83%之间。储存时间长短与过滤测试未通过之间似乎没有任何关联。

结论

结果表明,大多数在仓库条件下储存长达10年的N95过滤式面罩呼吸器可能具有预期的过滤性能水平,且过滤效率下降程度可能因型号而异。

相似文献

1
Evaluation of the filtration performance of 21 N95 filtering face piece respirators after prolonged storage.
Am J Infect Control. 2009 Jun;37(5):381-386. doi: 10.1016/j.ajic.2008.09.021. Epub 2009 Feb 1.
2
Total inward leakage measurement of particulates for N95 filtering facepiece respirators--a comparison study.
Ann Occup Hyg. 2014 Mar;58(2):206-16. doi: 10.1093/annhyg/met054. Epub 2013 Oct 9.
4
5
Performance of N95 FFRs Against Combustion and NaCl Aerosols in Dry and Moderately Humid Air: Manikin-based Study.
Ann Occup Hyg. 2016 Jul;60(6):748-60. doi: 10.1093/annhyg/mew019. Epub 2016 Apr 19.
8
Nanoparticle filtration performance of filtering facepiece respirators and canister/cartridge filters.
J Occup Environ Hyg. 2013;10(9):519-25. doi: 10.1080/15459624.2013.818229.
9
Manikin-based performance evaluation of N95 filtering-facepiece respirators challenged with nanoparticles.
Ann Occup Hyg. 2006 Apr;50(3):259-69. doi: 10.1093/annhyg/mei058. Epub 2005 Dec 12.
10
A comparison of facemask and respirator filtration test methods.
J Occup Environ Hyg. 2017 Feb;14(2):92-103. doi: 10.1080/15459624.2016.1225157.

引用本文的文献

1
Biodegradable Electret Filters Based on Beeswax-Modified Fibers: A Novel Production Strategy.
Polymers (Basel). 2025 Mar 20;17(6):813. doi: 10.3390/polym17060813.
2
Physical interventions to interrupt or reduce the spread of respiratory viruses.
Cochrane Database Syst Rev. 2023 Jan 30;1(1):CD006207. doi: 10.1002/14651858.CD006207.pub6.
3
Hydrogen Peroxide Methods for Decontaminating N95 Filtering Facepiece Respirators.
Appl Biosaf. 2021 Jun 1;26(2):71-79. doi: 10.1089/apb.20.0042. Epub 2021 Jun 2.
4
Mask decontamination methods (model N95) for respiratory protection: a rapid review.
Syst Rev. 2021 Aug 7;10(1):219. doi: 10.1186/s13643-021-01742-1.
5
Quantitative fit testing of filtering face-piece respirators during the COVID-19 pandemic reveals anthropometric deficits in most respirators available in Iran.
J Environ Health Sci Eng. 2021 Apr 15;19(1):805-817. doi: 10.1007/s40201-021-00648-3. eCollection 2021 Jun.
6
Gamma radiation sterilization of N95 respirators leads to decreased respirator performance.
PLoS One. 2021 Apr 8;16(4):e0248859. doi: 10.1371/journal.pone.0248859. eCollection 2021.
7
Disinfection of from N95 respirators with ozone: a pilot study.
BMJ Open Respir Res. 2021 Jan;8(1). doi: 10.1136/bmjresp-2020-000781.
8
9
Physical interventions to interrupt or reduce the spread of respiratory viruses.
Cochrane Database Syst Rev. 2020 Nov 20;11(11):CD006207. doi: 10.1002/14651858.CD006207.pub5.

本文引用的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验