Gordon J Eric, Chen Ryan C, Dobbs Matthew B, Luhmann Scott J, Rich Margaret M, Schoenecker Perry L
Department of Orthopaedic Surgery, Washington University School of Medicine, St Louis, MO, USA.
J Pediatr Orthop. 2009 Apr-May;29(3):281-4. doi: 10.1097/BPO.0b013e31819b9188.
The lateral distal femoral angle (LDFA), the medial proximal tibial angle (MPTA), and the mechanical axis deviation (MAD) are commonly used in the evaluation of lower extremity deformities. The interobserver and intraobserver reliabilities of these measurements have not been evaluated.
Three groups of observers with different levels of experience (5 attending pediatric orthopaedic surgeons, 5 orthopaedic chief residents, and 5 interns) measured the LDFA, MPTA, and MAD on 35 full-length standing anteroposterior teleroentgenograms (56extremities). Relatively equal numbers of extremities with varus, valgus, and normal alignments were chosen to represent a spectrum of lower extremities that might be encountered clinically. Measurements were performed in random order by each observer on 2 separate occasions separated by at least 2 weeks.
The interobserver and intraobserver reliabilities for each of the measurements regardless of the level of experience was greater than or equal to 0.90. The interobserver differences were slightly greater than the intraobserver differences for all measurements. The overall mean interobserver differences for angular and MAD measurements were within 1.6 degrees and 3.1 mm, respectively. The overall mean intraobserver differences for angular and MAD measurements were within 1.4 degrees and 1.9 mm, respectively. Reliability and mean differences were consistent regardless of the level of experience.
Measurement of the LDFA, MPTA, and MAD demonstrated excellent intraobserver and interobserver reliabilities regardless of the experience of the observer.
股骨远端外侧角(LDFA)、胫骨近端内侧角(MPTA)和机械轴偏移(MAD)常用于评估下肢畸形。尚未评估这些测量的观察者间和观察者内信度。
三组具有不同经验水平的观察者(5名小儿骨科主治医师、5名骨科住院总医师和5名实习医生)在35张全长站立位前后位远距离X线片(56个肢体)上测量LDFA、MPTA和MAD。选择相对数量相等的内翻、外翻和正常对线的肢体,以代表临床上可能遇到的一系列下肢情况。每位观察者以随机顺序在至少间隔2周的2个不同时间进行测量。
无论经验水平如何,每项测量的观察者间和观察者内信度均大于或等于0.90。所有测量的观察者间差异略大于观察者内差异。角度测量和MAD测量的总体平均观察者间差异分别在1.6度和3.1毫米以内。角度测量和MAD测量的总体平均观察者内差异分别在1.4度和1.9毫米以内。无论经验水平如何,信度和平均差异都是一致的。
无论观察者的经验如何,LDFA、MPTA和MAD的测量都显示出极好的观察者内和观察者间信度。