Suppr超能文献

动态轮廓眼压计与Goldmann压平眼压计的比较及其与角膜特性、屈光不正和眼动脉搏动幅度的关系。

Comparison of dynamic contour tonometry and Goldmann applanation tonometry and their relationship to corneal properties, refractive error, and ocular pulse amplitude.

作者信息

Erickson Dina H, Goodwin Denise, Rollins Michael, Belaustegui Amber, Anderson Chad

机构信息

Pacific University College of Optometry, Forest Grove, Oregon 97116, USA.

出版信息

Optometry. 2009 Apr;80(4):169-74. doi: 10.1016/j.optm.2009.01.013.

Abstract

BACKGROUND

Accurate intraocular pressure (IOP) measurement is essential in diagnosing and managing glaucoma. Dynamic contour tonometry (DCT) is less dependent on corneal properties, such as thickness, elasticity, and rigidity, than Goldmann applanation tonometry (GAT). This study examined the relationship between GAT and DCT as well as their relationship with corneal properties and ocular pulse amplitude (OPA).

METHODS

GAT, DCT, OPA, pachymetry, refractive error, and corneal curvature measurements were obtained on 115 healthy volunteers.

RESULTS

Participants with thicker corneas (>or=580 microm) had higher IOP measurements with GAT than DCT (P = 0.005). Those with thinner corneas (<or=520 microm) had lower IOP with GAT versus DCT (P = 0.008). GAT and DCT readings did not differ significantly in corneas with average thickness (521 to 579 microm). A clinically significant IOP difference between DCT and GAT was found in 18.2% of subjects. A correlation was found between OPA and both refractive error and IOP (R(2) = .343, P < 0.0001). OPA was higher with increased IOP and decreased myopia.

CONCLUSION

DCT provides IOP measurements that are less dependent on corneal factors than GAT, aiding in diagnosis and treatment of patients with ocular hypertension and glaucoma. Additional studies are necessary to examine the relationship between OPA, refractive error, and IOP and its possible association with increased incidence of glaucoma in myopic patients.

摘要

背景

准确测量眼压对于青光眼的诊断和治疗至关重要。动态轮廓眼压计(DCT)相比戈德曼压平眼压计(GAT),对角膜特性(如厚度、弹性和硬度)的依赖性较小。本研究探讨了GAT与DCT之间的关系,以及它们与角膜特性和眼脉搏振幅(OPA)的关系。

方法

对115名健康志愿者进行了GAT、DCT、OPA、角膜测厚、屈光不正和角膜曲率测量。

结果

角膜较厚(≥580微米)的参与者,GAT测量的眼压高于DCT(P = 0.005)。角膜较薄(≤520微米)的参与者,GAT测量的眼压低于DCT(P = 0.008)。平均厚度(521至579微米)的角膜,GAT和DCT读数无显著差异。18.2%的受试者中发现DCT和GAT之间存在具有临床意义的眼压差异。发现OPA与屈光不正和眼压均相关(R² = 0.343,P < 0.0001)。随着眼压升高和近视度数降低,OPA升高。

结论

与GAT相比,DCT测量眼压时对角膜因素的依赖性较小,有助于高眼压症和青光眼患者的诊断和治疗。需要进一步研究来探讨OPA、屈光不正和眼压之间的关系,以及其与近视患者青光眼发病率增加的可能关联。