Liu W Z, Peng W B, Yang C H
Hubei Provincial Institute for Drug Control, Wuhan.
Yao Xue Xue Bao. 1991;26(4):315-9.
A description is given for the preparation of flow through sensor and of the incorporation of the sensor into a flow injection analysis system. The parameters affecting the measurement are discussed. An accurate, convenient and rapid method is proposed for the determination of berberine-type alkaloids in various Chinese patent medicines (Coptis chinensis Franch., Phellodendron chinesis Schneid., xianglian wan, zuojin wan, ermiao wan and sanmiao wan). The slope is 54-60 mV/decade over the concentration range of 10(-3)-3 x 10(-6) mol/L berberine at pH 2-9.5. Direct potentiometry determination of berberine in various samples showed an average recovery of 99.5-103.5% and a relative standard deviation of 1.3-3.5% at a sampling rate of 120/h.
本文描述了流通式传感器的制备方法以及将该传感器集成到流动注射分析系统中的方法。讨论了影响测量的参数。提出了一种准确、便捷且快速的方法,用于测定多种中成药(黄连、黄柏、香连丸、左金丸、二妙丸和三妙丸)中的小檗碱型生物碱。在pH值为2 - 9.5时,黄连素浓度范围为10(-3)-3×10(-6) mol/L时,斜率为54 - 60 mV/十年。对各种样品中小檗碱的直接电位法测定表明,在采样速率为120/小时的情况下,平均回收率为99.5 - 103.5%,相对标准偏差为1.3 - 3.5%。