Chen Ming, Sweeney Henry W, Luke Becky, Chen Mindy, Brown Mathew
University of Hawaii, Honolulu, Hawaii, USA.
Clin Ophthalmol. 2009;3:401-3. doi: 10.2147/opth.s6135. Epub 2009 Jul 14.
Cumulative dissipated energy (CDE) was used with Infiniti((R)) Vision System (Alcon Labs) as an energy delivery guide to compare four different phaco techniques and phaco settings. The supracapsular phaco technique and burst mode is known for efficiency and surgery is faster compared with the old phaco unit. In this study, we found that supracapsular phaco with burst mode had the least CDE in both cataract and nuclear sclerosis cataract with the new Infiniti((R)) unit. We suggest that CDE can be used as one of the references to modify technique and setting to improve outcome for surgeons, especially for new surgeons.
累积耗散能量(CDE)与英菲尼迪(Infiniti)视觉系统(爱尔康实验室)一起用作能量传递指南,以比较四种不同的超声乳化技术和超声乳化设置。与旧的超声乳化设备相比,囊上超声乳化技术和爆破模式以高效著称,手术速度更快。在本研究中,我们发现使用新型英菲尼迪设备时,囊上超声乳化联合爆破模式在白内障和核性硬化性白内障中产生的CDE最少。我们建议CDE可作为修改技术和设置的参考之一,以改善外科医生的手术效果,尤其是新外科医生。