Melcher Jennifer R, Levine Robert A, Bergevin Christopher, Norris Barbara
Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA 02114, USA.
Hear Res. 2009 Nov;257(1-2):63-74. doi: 10.1016/j.heares.2009.08.005. Epub 2009 Aug 20.
Sound-evoked fMRI activation of the inferior colliculi (IC) was compared between tinnitus and non-tinnitus subjects matched in threshold (normal), age, depression, and anxiety. Subjects were stimulated with broadband sound in an "on/off" fMRI paradigm with and without on-going sound from the scanner coolant pump. (1) With pump sounds off, the tinnitus group showed greater stimulus-evoked activation of the IC than the non-tinnitus group, suggesting abnormal gain within the auditory pathway of tinnitus subjects. (2) Having pump sounds on reduced activation in the tinnitus, but not the non-tinnitus group. This result suggests response saturation in tinnitus subjects, possibly occurring because abnormal gain increased response amplitude to an upper limit. (3) In contrast to Melcher et al. (2000), the ratio of activation between right and left IC did not differ significantly between tinnitus and non-tinnitus subjects or in a manner dependent on tinnitus laterality. However, new data from subjects imaged previously by Melcher et al. suggest a possible tinnitus subgroup with abnormally asymmetric function of the IC. The present and previous data together suggest elevated responses to sound in the IC are common among those with tinnitus and normal thresholds, while abnormally asymmetric activation is not, even among those with lateralized tinnitus.
在阈值(正常)、年龄、抑郁和焦虑方面相匹配的耳鸣患者与非耳鸣患者之间,比较了下丘(IC)的声音诱发功能磁共振成像激活情况。在“开/关”功能磁共振成像范式中,使用宽带声音对受试者进行刺激,同时开启和关闭扫描仪冷却泵的持续声音。(1)在泵声音关闭的情况下,耳鸣组的IC刺激诱发激活比非耳鸣组更大,这表明耳鸣患者听觉通路内存在异常增益。(2)开启泵声音会降低耳鸣组的激活,但不会降低非耳鸣组的激活。这一结果表明耳鸣患者存在反应饱和,可能是因为异常增益将反应幅度提高到了上限。(3)与梅尔彻等人(2000年)的研究结果相反,耳鸣患者与非耳鸣患者之间或与耳鸣侧别相关的方式中,左右IC之间的激活比率没有显著差异。然而,梅尔彻等人之前成像的受试者的新数据表明,可能存在一个IC功能异常不对称的耳鸣亚组。目前和之前的数据共同表明,在耳鸣且阈值正常的人群中,IC对声音的反应增强很常见,而即使在有单侧耳鸣的人群中,异常不对称激活也不常见。