Suppr超能文献

因迟发性食管瘘导致颈椎螺钉缺失:病例报告

Cervical screw missing secondary to delayed esophageal fistula: case report.

作者信息

Cagli Sedat, Isik H Serdar, Zileli Mehmet

机构信息

Ege University, Department of Neurosurgery, Izmir, Turkey.

出版信息

Turk Neurosurg. 2009 Oct;19(4):437-40.

Abstract

Although anterior surgical approaches to the cervical spine have become popular and safe in recent years, they also have some complications. We present a case of loss of an anterior cervical plate screw by the natural tracts. The patient was a 47- year-old woman who was operated on for cervical spondylotic myelopathy at another institution. Surgical interference included two levels of anterior discectomy, iliac graft placement and fixation using plate and screws. Two years later, plate dislocation and partial migration of the upper screws were observed. After 7 years the patient complained of dysphagia and she accepted removal of the osteosynthesis. Radiographical examination showed that one of the upper screws was missing and two lower screws were broken. Esophageal perforation was found during the surgery and repaired. Further progress was favourable. Complications associated with esophageal perforation may range from massive infection and death to spontaneous recovery. Erosion of the esophageal wall due to extruded bulky constructs may lead to a persistent fistula, abscess or septic diffusion. Spontaneous perforation of the esophagus and screw loss via the gastrointestinal tract make this case interesting..

摘要

尽管近年来颈椎前路手术方法已变得流行且安全,但它们也存在一些并发症。我们报告一例颈椎前路钢板螺钉经自然通道丢失的病例。患者为一名47岁女性,曾在另一机构接受颈椎病性脊髓病手术。手术干预包括两个节段的前路椎间盘切除术、髂骨植骨以及使用钢板和螺钉进行固定。两年后,观察到钢板移位和上方螺钉部分移位。7年后,患者主诉吞咽困难,遂接受内固定取出术。影像学检查显示上方一枚螺钉缺失,下方两枚螺钉断裂。手术中发现食管穿孔并进行了修复。后续进展顺利。与食管穿孔相关的并发症范围可能从严重感染和死亡到自发恢复。由于植入物突出导致食管壁侵蚀可能会导致持续性瘘管、脓肿或感染扩散。食管自发穿孔以及螺钉经胃肠道丢失使得该病例颇具趣味性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验