Suppr超能文献

光学相干断层扫描对接触镜上动态泪膜变化的超高分辨率测量。

Ultrahigh-resolution measurement by optical coherence tomography of dynamic tear film changes on contact lenses.

机构信息

School of Ophthalmology and Optometry, Wenzhou Medical College, Wenzhou, Zhejiang, China.

出版信息

Invest Ophthalmol Vis Sci. 2010 Apr;51(4):1988-93. doi: 10.1167/iovs.09-4389. Epub 2009 Nov 20.

Abstract

Purpose. To determine the dynamic pre- and postlens tear film (PLTF and PoLTF) thicknesses by using optical coherence tomography (OCT). Methods. Ultrahigh-resolution OCT was used to image the tear film of 22 subjects before and after contact lens wear. A soft lens with 1 drop of artificial tears on its concave surface was inserted onto one randomly selected eye. OCT images were taken before insertion, immediately afterward, and every 2 minutes for 10 minutes. For the contralateral eye, the lens inserted was not prewetted on the concave surface. OCT images were taken before insertion, immediately afterward, and at 3 minutes. Then another drop was instilled, and images were taken immediately afterward and every 2 minutes for 10 minutes. Images were processed by custom software to yield tear film thickness. Results. The thickness of precorneal tear film (PCTF) was 1.9 +/- 0.9 mum. The PoLTF was visualized clearly in all cases immediately after lens insertion, with 1 drop on the lens concave surface. Through the first 6 minutes after insertion, the PoLTF was greater than the PCTF. The PLTF (n = 12) and PoLTF (n = 9) were visualized immediately after lens insertion. After 3 minutes, the PLTF in most subjects and PoLTF in all subjects were invisible. The thickness of the PLTF increased after the instillation of artificial tears, whereas the PoLTF did not at any checkpoint for 10 minutes. Conclusions. Ultrahigh-resolution OCT is a promising tool for measuring the tear film. The PoLTF did not increase after instillation of artificial tears.

摘要

目的。利用光学相干断层扫描(OCT)确定预镜片和后镜片泪膜(PLTF 和 PoLTF)的动态厚度。

方法。使用超高分辨率 OCT 对 22 名受试者在接触镜佩戴前后的泪膜进行成像。将一滴人工泪液滴在凹面的软性隐形眼镜插入一只随机选择的眼睛。在插入前、插入后立即以及随后每 2 分钟拍摄一次 OCT 图像,共 10 分钟。对于对侧眼睛,插入的镜片在凹面没有预先润湿。在插入前、插入后立即以及 3 分钟拍摄 OCT 图像。然后再滴一滴,立即拍摄图像,并随后每 2 分钟拍摄一次,共 10 分钟。通过定制软件处理图像以获得泪膜厚度。

结果。角膜前泪膜(PCTF)的厚度为 1.9 ± 0.9 μm。在所有情况下,在插入镜片后立即可以清楚地看到 PoLTF,在镜片凹面滴一滴。在插入后的前 6 分钟内,PoLTF 大于 PCTF。在插入后立即可以看到 PLTF(n = 12)和 PoLTF(n = 9)。3 分钟后,大多数受试者的 PLTF 和所有受试者的 PoLTF 都不可见。人工泪液滴注后 PLTF 厚度增加,而在 10 分钟的任何时间点 PoLTF 均未增加。

结论。超高分辨率 OCT 是测量泪膜的一种很有前途的工具。在人工泪液滴注后,PoLTF 没有增加。

相似文献

引用本文的文献

3
Diagnosis of Keratitis: Past, Present and Future.角膜炎的诊断:过去、现在与未来
Diagnostics (Basel). 2023 Aug 11;13(16):2655. doi: 10.3390/diagnostics13162655.
9
Advances in Dry Eye Disease Examination Techniques.干眼症检查技术的进展
Front Med (Lausanne). 2022 Jan 25;8:826530. doi: 10.3389/fmed.2021.826530. eCollection 2021.

本文引用的文献

3
Upper and lower tear menisci on contact lenses.隐形眼镜上的上、下泪液半月板。
Invest Ophthalmol Vis Sci. 2009 Mar;50(3):1106-11. doi: 10.1167/iovs.08-2458. Epub 2008 Sep 29.
10
Thinning rate of the precorneal and prelens tear films.角膜前和晶状体前泪膜的变薄率。
Invest Ophthalmol Vis Sci. 2005 Jul;46(7):2353-61. doi: 10.1167/iovs.05-0094.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验