Invest Ophthalmol Vis Sci. 1991 Feb;32(2):416-21.
The authors assessed relationships between visual acuity and the amplitude, frequency, intensity, and duration of foveation periods in a retrospective study of 32 patients. Twenty-four patients had congenital idiopathic nystagmus, and eight patients had nystagmus and albinism. Visual acuity was determined for Landolt ring optotypes and, as the extrapolated high-frequency cutoff of the contrast sensitivity function, for horizontal and vertical gratings. No significant correlation existed between acuity and any measured eye movement parameter; however, optotype acuity was related to the magnitude of astigmatic refractive correction, both in patients with idiopathic nystagmus and in albinos. In a subgroup of patients with idiopathic nystagmus whose astigmatic refractive error was -1.50 D or less, nystagmus intensity (amplitude x frequency) correlated significantly with acuity for optotypes (r = 0.71), but not for gratings. Although resolution for vertical gratings was correlated with astigmatic refractive correction, the ratio of resolution for gratings parallel and orthogonal to the meridian of nystagmus was not. Thus, the belief that poorer acuity in patients with substantial astigmatism is attributable to an optically induced meridional amblyopia is supported only partly by these results. The authors concluded that among patients with congenital nystagmus, the influence of eye motion on visual acuity is not readily predicted either from the parameters of nystagmus that they evaluated or from the comparison of resolution for horizontal and vertical gratings.
作者在一项对32例患者的回顾性研究中评估了视力与注视期的幅度、频率、强度和持续时间之间的关系。24例患者患有先天性特发性眼球震颤,8例患者患有眼球震颤和白化病。采用Landolt环视标测定视力,并以对比敏感度函数的外推高频截止值为指标,测定水平和垂直光栅的视力。视力与任何测量的眼动参数之间均无显著相关性;然而,视标视力与散光屈光矫正的程度有关,无论是特发性眼球震颤患者还是白化病患者。在散光屈光不正为-1.50 D或更低的特发性眼球震颤患者亚组中,眼球震颤强度(幅度×频率)与视标视力显著相关(r = 0.71),但与光栅视力无关。虽然垂直光栅的分辨力与散光屈光矫正相关,但与眼球震颤子午线平行和垂直的光栅分辨力之比却无关。因此,这些结果仅部分支持了散光严重患者视力较差归因于光学诱导的子午线弱视这一观点。作者得出结论,在先天性眼球震颤患者中,无论是从他们评估的眼球震颤参数,还是从水平和垂直光栅分辨力的比较中,都不容易预测眼动对视力的影响。