Associate Professor, Department of Dental Materials and Prosthodontics, Araçatuba Dental School, São Paulo State University (UNESP), São Paulo, Brazil.
J Prosthet Dent. 2009 Dec;102(6):385-92. doi: 10.1016/S0022-3913(09)60200-6.
Acrylic resin denture teeth are widely used due to the chemical bond to the acrylic resin of the denture base. However, discoloration of acrylic resin denture teeth can be a problem.
The purpose of this study was to investigate the effect of polymerization methods and thermal cycling on the color change of acrylic resin denture teeth.
Ten different brands of acrylic resin denture teeth were evaluated: Art Plus (AP), Biolux (BX), Biotone IPN (BI), Magister (MG), Mondial 6 (MD), Premium 6 (PR), SR Vivodent PE (SR), Trilux (TR), Trubyte Biotone (TB), and Vipi Dent Plus (VP). Each brand was divided into 2 groups (n=12); each group was subjected to 1 of 2 polymerization methods (microwave, 500 W for 3 minutes, or water bath, 74 degrees C for 9 hours). After polymerization, all of the specimens were thermal cycled between 5 degrees C and 55 degrees C with 30-second dwell times for 5000 cycles. The specimen colors were measured with a spectrophotometer, using the CIE Lab* system, at baseline (B), after polymerization (P), and after thermal cycling (T). Color differences (DeltaE) were calculated for periods between P and B (PB), T and B (TB), and T and P (TP). A DeltaE of < or =3.3 was considered clinically acceptable. The data were evaluated by 3-way repeated-measures ANOVA and the Tukey HSD test (alpha=.05).
The highest DeltaE values were obtained for BI and SR teeth; these were significantly higher than the values obtained for the other brands (P<.05). There was no significant difference between the 2 polymerization methods. There was no significant difference between TB and PB for either polymerization method.
The DeltaE values are within acceptable clinical limits for all brands, for both polymerization methods and different measurement periods.
由于丙烯酸树脂基托与丙烯酸树脂之间的化学键,丙烯酸树脂义齿牙被广泛使用。然而,丙烯酸树脂义齿牙的变色可能是一个问题。
本研究的目的是研究聚合方法和热循环对丙烯酸树脂义齿牙颜色变化的影响。
评估了 10 种不同品牌的丙烯酸树脂义齿牙:Art Plus(AP)、Biolux(BX)、Biotone IPN(BI)、Magister(MG)、Mondial 6(MD)、Premium 6(PR)、SR Vivodent PE(SR)、Trilux(TR)、Trubyte Biotone(TB)和 Vipi Dent Plus(VP)。每个品牌分为 2 组(n=12);每组采用 2 种聚合方法之一(微波,500 W 3 分钟或水浴,74°C 9 小时)。聚合后,所有样本均在 5°C 和 55°C 之间进行热循环,停留时间为 30 秒,循环 5000 次。使用 CIE Lab*系统,通过分光光度计在基线(B)、聚合后(P)和热循环后(T)测量样本颜色。计算 P 与 B(PB)、T 与 B(TB)和 T 与 P(TP)之间的颜色差异(DeltaE)。DeltaE<或=3.3 被认为具有临床可接受性。使用 3 因素重复测量方差分析和 Tukey HSD 检验(alpha=.05)评估数据。
BI 和 SR 牙的 DeltaE 值最高;与其他品牌相比,这些值显著更高(P<.05)。两种聚合方法之间无显著差异。对于两种聚合方法,TB 和 PB 之间无显著差异。
对于所有品牌,对于两种聚合方法和不同的测量周期,DeltaE 值均在临床可接受范围内。