基于树脂的牙科材料在LED和卤素灯固化下的单体释放

Monomer Release from Resin Based Dental Materials Cured With LED and Halogen Lights.

作者信息

Ak Asli Topaloglu, Alpoz A Riza, Bayraktar Oguz, Ertugrul Fahinur

机构信息

Research Assistant, Ege University, School of Dentistry, Department of Paediatric Dentistry, Izmir, Turkey.

出版信息

Eur J Dent. 2010 Jan;4(1):34-40.

Abstract

OBJECTIVES

To measure the release of TEGDMA and BisGMA from two commercially available composite resins; Filtek Z 250 (3M ESPE, Germany), Leaddent (Leaddent, Germany) and two fissure sealants; Helioseal F (3M ESPE, Germany) Enamel Loc (Premiere Rev, USA) over 1, 3 and 7 days after polymerization with standard quartz-tungsten halogen Coltolux II (QHL) (Coltene Switzerland) and a standard blue light emitting diode Elipar Freelight 2 (3M ESPE, Germany).

METHODS

9 samples of each material were placed in disc shaped specimens in 1 mm of thickness and 10 mm in diameter (n=36). Each material was polymerized using LED for 20 s (n=12), 40 s (n=12) and halogen for 40 s (n=12), respectively. High Performance Liquid Chromatography (HPLC) was used to measure the amount of monomers released over 1, 3 and 7 days. Data was analyzed using one way ANOVA and Bonferroni test for multiple comparisons with a significance level of .05.

RESULTS

LED 20 sec group showed the highest release of monomers at 1, 3 and 7 days in sealant groups. Halogen 40 sec group resulted highest release of monomers for Leaddent at all time intervals (P<.05)

CONCLUSIONS

Efficiency of the curing unit and applying the recommended curing time of the light activated resin based dental materials is very important to protect the patient from potential hazards of residual monomers.

摘要

目的

测量两种市售复合树脂(德国3M ESPE公司的Filtek Z 250、德国Leaddent公司的Leaddent)以及两种窝沟封闭剂(德国3M ESPE公司的Helioseal F、美国Premiere Rev公司的Enamel Loc)在使用标准石英-钨卤素灯Coltolux II(瑞士Coltene公司)和标准蓝光发光二极管Elipar Freelight 2(德国3M ESPE公司)聚合1天、3天和7天后TEGDMA和BisGMA的释放量。

方法

每种材料制备9个厚度为1mm、直径为10mm的圆盘形样本(n = 36)。每种材料分别使用LED灯照射20秒(n = 12)、40秒(n = 12)以及卤素灯照射40秒(n = 12)进行聚合。采用高效液相色谱法(HPLC)测量1天、3天和7天后释放的单体量。使用单因素方差分析和Bonferroni检验进行数据分析,多重比较的显著性水平为0.05。

结果

在窝沟封闭剂组中,LED灯照射20秒组在1天、3天和7天时单体释放量最高。在所有时间间隔内,卤素灯照射40秒组的Leaddent单体释放量最高(P < 0.05)。

结论

固化设备的效率以及应用光固化树脂基牙科材料的推荐固化时间对于保护患者免受残留单体的潜在危害非常重要。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3fd9/2798788/4ae25a53facf/page_36_01.jpg

相似文献

6
Evaluation of the Impact of Irradiance Lamps and Storage Media on Elution of TEGDMA from Dental Composites.
Eur J Dent. 2025 Feb;19(1):61-69. doi: 10.1055/s-0044-1786876. Epub 2024 May 24.
7
HPLC analysis of eluted monomers from two composite resins cured with LED and halogen curing lights.
J Biomed Mater Res B Appl Biomater. 2009 Jan;88(1):191-6. doi: 10.1002/jbm.b.31167.
8
Depth of cure and surface microhardness of composite resin cured with blue LED curing lights.
Dent Mater. 2004 May;20(4):364-9. doi: 10.1016/S0109-5641(03)00130-1.
9
Effect of light dispersion of LED curing lights on resin composite polymerization.
J Esthet Restor Dent. 2005;17(4):244-54; discussion 254-5. doi: 10.1111/j.1708-8240.2005.tb00122.x.

引用本文的文献

1
A comparative in vitro study on monomer release from flash-free or conventional bonding systems.
Clin Oral Investig. 2025 Mar 6;29(3):169. doi: 10.1007/s00784-025-06250-3.
2
Evaluation of the amount of residual monomer released from different flowable composite resins.
BMC Oral Health. 2024 Feb 15;24(1):244. doi: 10.1186/s12903-024-04005-2.
5
Laboratory methods to simulate the mechanical degradation of resin composite restorations.
Dent Mater. 2022 Jan;38(1):214-229. doi: 10.1016/j.dental.2021.12.006. Epub 2021 Dec 20.
6
Assessment of Cytotoxic and Genotoxic Effect of Fissure Sealants in Buccal Epithelial Cells.
Acta Stomatol Croat. 2021 Mar;55(1):10-17. doi: 10.15644/asc55/1/2.
7
Degree of Conversion and Oxygen-Inhibited Layer Effect of Three Dental Adhesives.
Dent J (Basel). 2016 Oct 27;4(4):37. doi: 10.3390/dj4040037.
8
Leaching of monomers from bulk-fill composites: An in vitro study.
J Conserv Dent. 2016 Sep-Oct;19(5):482-6. doi: 10.4103/0972-0707.190020.

本文引用的文献

5
Evaluation of residual monomer elimination methods in three different fissure sealants in vitro.
J Oral Rehabil. 2005 Feb;32(2):116-21. doi: 10.1111/j.1365-2842.2004.01405.x.
8
Light-curing technology: past, present, and future.
Compend Contin Educ Dent. 2002 Sep;23(9 Suppl 1):18-24.
9
Polymerization efficiency of LED curing lights.
J Esthet Restor Dent. 2002;14(5):286-95. doi: 10.1111/j.1708-8240.2002.tb00524.x.
10

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验