[The Dosage and Quality of Imaging program and quality assurance in mammography].

作者信息

Rimondi O, Gambaccini M, Marziani M, Candini G C, Indovina P L, Toti A, De Guglielmo E, Calicchia A

机构信息

Dipartimento di Fisica, Università, Ferrara.

出版信息

Radiol Med. 1991 Jan-Feb;81(1-2):69-72.

PMID:2006340
Abstract

The aim of the optimization program for mammography (DQM) in Italy is to achieve the best compromise between image quality and dose to patient. 272 centers agreed to the second phase of the program, from February 1987 to January 1990. Exposure, half-value layer (HVL) and focal spot size were measured according to the same methods employed in the first phase of the DQM program (1985), while image quality was evaluated by means of a new performance phantom. The average exposure was 0.96 R (2.48 x 10(-4) C/kg); in 173 (64.3%) centers exposure was less than 1 R (2.58 x 10(-4) C/kg), and only in 3 centers, where a direct X-ray film was employed, was exposure greater than 5 R (12.9 x 10(-4) C/kg). In every center the average whole-breast dose to a reference organ (5 cm thick, composed of 50% fat + 50% water) was calculated on the basis of entrance exposure, HVL, and focus-skin distance; in 63.2% of the centers doses less than 0.15 cGy were employed. The results allowed dose and image quality to be correlated in order to divide the centers (using a film-screen system) into groups with a different efficiency level: in 101 centers dose and image quality were good, in 64 centers too high a dose was employed, in 66 centers image quality was poor, and in 38 centers dose was too high and image quality was poor. It must be stressed that the DQM program can play its role only if each center carries out its Quality Assurance activity after the methods recommended by the World Health Organization.

摘要

相似文献

1
[The Dosage and Quality of Imaging program and quality assurance in mammography].
Radiol Med. 1991 Jan-Feb;81(1-2):69-72.
2
[Quality assurance of mammography in the province of Trent].
Radiol Med. 1993 Sep;86(3):240-6.
3
[The dose and quality program in mammography (DQM). Results of the study carried out in 20 Fruili-Venezia Giulia centers].
Radiol Med. 1993 Dec;86(6):893-8.
4
[The procedures and results of a quality control program in mammography carried out on a regional basis].
Radiol Med. 1996 Mar;91(3):187-93.
5
Reference levels for image quality in mammography.
Radiat Prot Dosimetry. 2008;129(1-3):170-2. doi: 10.1093/rpd/ncn080. Epub 2008 Mar 28.
6
Evaluation of a new mammographic film: methods and considerations.
Health Phys. 2008 Apr;94(4):338-44. doi: 10.1097/01.HP.0000298225.97830.a4.
7
[X-ray phase imaging using a X-ray tube with a small focal spot -improvement of image quality in mammography-].[使用具有小焦点的X射线管进行X射线相位成像——乳腺摄影图像质量的改善——]
Igaku Butsuri. 2002;22(1):21-9.
8
Quality assurance in screening mammography.乳腺钼靶筛查中的质量保证
Health Devices. 1990 May-Jun;19(5-6):152-98.
9
Global quality control perspective for the physical and technical aspects of screen-film mammography--image quality and radiation dose.乳腺钼靶摄影物理和技术方面的全球质量控制视角——图像质量与辐射剂量
Radiat Prot Dosimetry. 2006;121(4):445-51. doi: 10.1093/rpd/ncl051. Epub 2006 May 18.
10
[Quality control of mammography: potential use of a new device for testing the image quality and the dose].
Radiol Med. 1996 Sep;92(3):261-6.