• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[The dose and quality program in mammography (DQM). Results of the study carried out in 20 Fruili-Venezia Giulia centers].

作者信息

Cressa C, Zuiani C, Bregant P, Vidimari R, de Guarrini F

机构信息

Instituto di Radiologia, Università di Trieste.

出版信息

Radiol Med. 1993 Dec;86(6):893-8.

PMID:8296013
Abstract

Recently, 20 breast centers in Friuli Venezia Giulia have been investigated for the mammography optimization program known as DQM (Dose and Quality in Mammography). This was the second trial, the first one dating 1987-1988 and including only 10 centers. The chosen parameters were evaluated by means of a performance phantom containing 15 details, a Victoreen 660 ionizing camera, a star pattern and several plexiglass phantoms of different thickness. Statistical-methodological data were collected by means of a questionnaire. The results of the trial were communicated to each center as well as directions for future improvements. All centers were found to use mammographic equipment with a molybdenum anode and the film-screen combination; 18 center use grids daily, while 11 can perform direct radiographic magnification. Only 40% of the examined centers use a dedicated daylight printer. The overall quality of the radiographic image was seen to be acceptable, as 8 or more details of 15 hidden in the phantom were visualized, in 16 of 20 centers. The mean glandular dose was below the minimum threshold in all centers: in 45% of cases it was below 1.5 mGy. The setting of the automatic exposition control system was found to be poor, especially that of the adjustment related to breast thickness. Acceptability thresholds were met only by 31% of the examined centers (density variations < 20%). Notwithstanding the identification of areas where improvements can be made also from a methodological point of view, we can conclude that the quality provided by regional breast centers is definitely adequate. Good image quality and acceptable doses were observed in 80% of the centers. The results are significant and encouraging when compared with those from the first DQM trial carried out in our region, which confirms the value of periodical quality programs.

摘要

相似文献

1
[The dose and quality program in mammography (DQM). Results of the study carried out in 20 Fruili-Venezia Giulia centers].
Radiol Med. 1993 Dec;86(6):893-8.
2
[The Dosage and Quality of Imaging program and quality assurance in mammography].
Radiol Med. 1991 Jan-Feb;81(1-2):69-72.
3
[Quality assurance of mammography in the province of Trent].
Radiol Med. 1993 Sep;86(3):240-6.
4
[The procedures and results of a quality control program in mammography carried out on a regional basis].
Radiol Med. 1996 Mar;91(3):187-93.
5
Quality assurance in screening mammography.乳腺钼靶筛查中的质量保证
Health Devices. 1990 May-Jun;19(5-6):152-98.
6
[Experimental investigations for dose reduction by optimizing the radiation quality for digital mammography with an a-Se detector].[利用非晶硒探测器优化数字乳腺摄影的辐射质量以降低剂量的实验研究]
Rofo. 2007 May;179(5):487-91. doi: 10.1055/s-2007-962983.
7
Optimization of tube potential-filter combinations for film-screen mammography: a contrast detail phantom study.乳腺钼靶摄影中管电压-滤过组合的优化:一项对比细节模体研究
Clin Imaging. 2005 Jul-Aug;29(4):246-50. doi: 10.1016/j.clinimag.2004.11.003.
8
Contrast-to-noise ratio in magnification mammography: a Monte Carlo study.放大乳腺摄影中的对比噪声比:一项蒙特卡洛研究。
Phys Med Biol. 2007 Jun 7;52(11):3185-99. doi: 10.1088/0031-9155/52/11/017. Epub 2007 May 10.
9
Review of the first 50 cases completed by the RACR mammography QA programme: phantom image quality, processor control and dose considerations.对RACR乳腺X线摄影质量保证计划完成的前50例病例的回顾:体模图像质量、处理器控制和剂量考量
Australas Radiol. 1997 Nov;41(4):387-91.
10
[Quality control of mammography: potential use of a new device for testing the image quality and the dose].
Radiol Med. 1996 Sep;92(3):261-6.