[The procedures and results of a quality control program in mammography carried out on a regional basis].

作者信息

Milano F, Rosselli Del Turco M, Maggi E, Certo N, Morrone D, Lazzeri B

机构信息

U. O. Fisica Medica, Dipartimento di Fisiopatologia Clinica, Università di Firenze.

出版信息

Radiol Med. 1996 Mar;91(3):187-93.

PMID:8628928
Abstract

In 1990 the region of Tuscany instituted a quality control program for mammography, in order to check the working conditions of mammography centers in the region, to investigate the feasibility of applying some working standards in line with European recommendations, and to promote the training of personnel. The program involves the following: a test of newly acquired mammographic equipment to establish that it meets the required standards; an annual test of generators, X-ray beams, grid, AEC, screen-film system, film processing, dose and image quality; daily test (phantom radiography and film sensitometry) performed by the personnel of each mammographic Unit; and a sustained advisory service for the technical problems occurring between checks. Thirty-nine of 57 centers participated on a voluntary basis, and 135 checks were performed annually. The results of the program show a performance below the recommended standard in relation to AEC, film sensitometry and the adequacy of lights in dark rooms in 40%, 50% and 63%, respectively, of the centers. Entrance exposure was over 1500 mR, with a maximum value of 3450 mR, in 6 cases in the first round. 5 cases in second, and only 1 case in the third. In general, the results are slightly improving, but mammography optimization is still a long way off. It is necessary to carry out suitable programs for quality control in mammography on a regional basis and to establish precise guidelines for individual mammographic Units to follow in order to meet the European standards.

摘要

相似文献

1
[The procedures and results of a quality control program in mammography carried out on a regional basis].
Radiol Med. 1996 Mar;91(3):187-93.
2
[Quality assurance of mammography in the province of Trent].
Radiol Med. 1993 Sep;86(3):240-6.
3
[The Dosage and Quality of Imaging program and quality assurance in mammography].
Radiol Med. 1991 Jan-Feb;81(1-2):69-72.
4
[The dose and quality program in mammography (DQM). Results of the study carried out in 20 Fruili-Venezia Giulia centers].
Radiol Med. 1993 Dec;86(6):893-8.
5
Mammographic equipment, technique, and quality control.
Curr Opin Radiol. 1991 Aug;3(4):571-8.
6
Confrontation of mammography systems in flanders with the European Guidelines for Quality Assurance in mammography screening. Analysis of initial results.比利时弗拉芒地区乳腺钼靶摄影系统与欧洲乳腺钼靶筛查质量保证指南的对比。初步结果分析。
JBR-BTR. 1999 Dec;82(6):288-93.
7
Quality assurance in screening mammography.乳腺钼靶筛查中的质量保证
Health Devices. 1990 May-Jun;19(5-6):152-98.
8
Implementation of the European protocol for quality control of the technical aspects of mammography screening in Bulgaria.在保加利亚实施欧洲乳腺X线筛查技术方面质量控制协议。
Radiat Prot Dosimetry. 2005;114(1-3):403-5. doi: 10.1093/rpd/nch569.
9
[Quality control of mammography: potential use of a new device for testing the image quality and the dose].
Radiol Med. 1996 Sep;92(3):261-6.
10
Performance measurements of mammographic systems.乳腺摄影系统的性能测量
Radiat Prot Dosimetry. 2008;129(1-3):165-9. doi: 10.1093/rpd/ncn141. Epub 2008 Apr 29.