Department of Nuclear Medicine, Institute of Radiation Medicine, Seoul National University College of Medicine, 110-744 Seoul, South Korea.
Nucl Med Biol. 2010 Feb;37(2):149-55. doi: 10.1016/j.nucmedbio.2009.10.010. Epub 2009 Nov 26.
Tris(4,6-dimethoxysalicylaldimine)-N,N'-bis(3-aminopropyl)-N,N'-ethylenediamine (BAPEN), a tris(salicylaldimine) derivative, is a heart positron emission tomography (PET) agent when labeled with (68)Ga. However, its labeling requires complicated and time-consuming procedures. In this study, the authors formulated a new BAPEN kit for convenient (68)Ga labeling.
BAPEN (0.25 mg) kits were prepared by dispensing its solution in 1 M sodium acetate buffer (pH 5.5) into sterile vials and lyophilization. The prepared kits were labeled with generator-eluted (68)Ga in 0.1 N HCl. Stability in human serum was tested. Expiration date was determined by accelerated testing according to US Food and Drug Administration guidelines. A Biodistribution study was performed in normal mice after injection via tail vein.
The prepared kits achieved radiolabeling efficiencies in excess of 95% and showed a shelf-life of 98 days at 25 degrees C and 64.3 months at 4 degrees C. (68)Ga-BAPEN was found to be stable in human serum at 37 degrees C for at least 1 h. Furthermore, a biodistribution study revealed high heart uptake (10.8% ID/g, 1 h).
The authors developed a BAPEN kit for convenient labeling with (68)Ga. The (68)Ga-BAPEN showed high stability and excellent biodistribution results in normal mice, which is required for myocardial PET imaging.
三(4,6-二甲氧基水杨醛亚胺)-N,N'-双(3-氨基丙基)-N,N'-乙二胺(BAPEN)是一种三(水杨醛亚胺)衍生物,当用(68)Ga 标记时,是一种心脏正电子发射断层扫描(PET)剂。然而,其标记需要复杂且耗时的程序。在这项研究中,作者制定了一种新的 BAPEN 试剂盒,方便(68)Ga 标记。
BAPEN(0.25mg)试剂盒通过将其溶液在 1M 乙酸钠缓冲液(pH5.5)中分配到无菌小瓶中并冻干来制备。将制备好的试剂盒用洗脱剂(68)Ga 在 0.1N HCl 中进行标记。在人血清中测试稳定性。根据美国食品和药物管理局的指南,通过加速测试确定有效期。通过尾静脉注射在正常小鼠中进行生物分布研究。
制备的试剂盒的放射性标记效率超过 95%,在 25°C 下的保质期为 98 天,在 4°C 下的保质期为 64.3 个月。(68)Ga-BAPEN 在 37°C 的人血清中至少 1 小时稳定。此外,生物分布研究表明,心脏摄取率高(10.8%ID/g,1h)。
作者开发了一种方便用(68)Ga 标记 BAPEN 的试剂盒。(68)Ga-BAPEN 在正常小鼠中表现出高稳定性和优异的生物分布结果,这是心肌 PET 成像所必需的。