Suppr超能文献

医院和城市废水中的四环素类抗生素:葡萄牙的一项初步研究。

Tetracycline antibiotics in hospital and municipal wastewaters: a pilot study in Portugal.

机构信息

Group of Health Surveillance, CEF, Faculty of Pharmacy, University of Coimbra, Health Sciences Campus, Azinhaga de Santa Comba, 3000-548 Coimbra, Portugal.

出版信息

Anal Bioanal Chem. 2010 Apr;396(8):2929-36. doi: 10.1007/s00216-010-3581-3. Epub 2010 Mar 6.

Abstract

This study investigated the occurrence of tetracyclines (TCs), namely minocycline (MIN), TC, and its epimer epitetracycline (ETC), and doxycycline (DC), in four hospital wastewater effluents and its fate in municipal wastewater treatment plants (WWTPs), in Coimbra, Portugal. Analytical determination was carried out by solid-phase extraction followed by liquid chromatography with fluorescence detection. A gradient system with a mobile phase containing oxalic acid 0.02 M and acetonitrile was used. After postcolumn derivatization with magnesium reagent, TCs were detected at lambda(exc) 386 nm and lambda(em) 500 nm. The proposed method allowed good sensitivity, accuracy, and precision. LOQs were 0.5 microg l(-1) for ETC and TC and 15 and 5 microg l(-1) for MIN and DC, respectively. The recovery values ranged between 66.4% and 117.1%, and intraday and interday repeatability was lower than 6.8%. The method was successfully used to determine the presence of the above-mentioned TCs in 24 wastewater composite samples obtained from hospital effluents and from influent and effluent of the WWTP located in Coimbra, Portugal. MIN and TC were found in 41.7% of the samples; ETC and DC were found in 25% and 8.3% of the samples, respectively. The levels found ranged from 6 to 531.7 microg l(-1) in hospital effluents, while its concentrations in WWTP ranged from 95.8 to 915.3 microg l(-1). A seasonal influence in the concentrations found has also been observed, the levels found in samples collected during spring being higher than those observed in samples collected during autumn; however, these are only preliminary results. The WWTP removal rate ranged between 89.5% and 100%.

摘要

本研究调查了四环素(TCs),即美满环素(MIN)、TC 及其差向异构体差向四环素(ETC)以及强力霉素(DC)在葡萄牙科英布拉的四个医院废水处理厂的排放情况及其在城市废水处理厂(WWTP)中的命运。通过固相萃取和荧光检测的液相色谱法进行分析测定。使用含有 0.02 M 草酸和乙腈的梯度系统。TCs 用镁试剂进行柱后衍生,在 lambda(exc) 386nm 和 lambda(em) 500nm 处检测。该方法具有良好的灵敏度、准确性和精密度。ETC 和 TC 的 LOQs 分别为 0.5μg l(-1),MIN 和 DC 的 LOQs 分别为 15 和 5μg l(-1)。回收率范围为 66.4%至 117.1%,日内和日间重复性低于 6.8%。该方法成功地用于测定来自医院废水和位于葡萄牙科英布拉的 WWTP 的进水和出水的 24 个废水混合样品中上述 TCs 的存在。在 41.7%的样品中发现了 MIN 和 TC;在 25%和 8.3%的样品中分别发现了 ETC 和 DC。在医院废水中发现的浓度范围为 6 至 531.7μg l(-1),而在 WWTP 中的浓度范围为 95.8 至 915.3μg l(-1)。还观察到浓度的季节性影响,在春季采集的样品中发现的水平高于在秋季采集的样品中观察到的水平;然而,这只是初步结果。WWTP 的去除率在 89.5%至 100%之间。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验