• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

The role of sedation and pulse oximetry during upper gastrointestinal endoscopy.

作者信息

Sharma S K, Maharjan D K, Thapa P B, Adhikari S B, Byenjankar B, Khadka S, Gurung R

机构信息

Department of Surgery, Kathmandu Medical College Teaching Hospital, Sinamangal, Kathmandu, Nepal.

出版信息

JNMA J Nepal Med Assoc. 2009 Apr-Jun;48(174):92-8.

PMID:20387345
Abstract

INTRODUCTION

To determine the changes in oxygen saturation, blood pressure and pulse rate during endoscopic procedure and to evaluate--oesophagogastroduodenoscopy (OGD) related discomfort assessed by the patient.

METHODS

It is observational case control study. Baseline pulse, blood pressure and oxygen saturation were monitored before procedure, at one minute of procedure, at five minute and soon after procedure. Patients were randomly selected according to lottery system (1: without sedation and 2: with sedation) and divided into two groups; without and with sedation. Before leaving department they were asked about level of discomfort during and after procedure.

RESULTS

Patient's mean age +/- SD: 36.65, +/- 11.42 years and 53.3% were men. Base line mean oxygen saturation among sedated patient were 96.77 +/-1.56 % and 97.23, +/- 2.26 % respectively (P = 0.358). Mild to moderate hypoxia was noted more in sedated patient than in non sedated patient. Severe hypoxia was noted in 3.3% of sedated patient. No statistically significant change was noticed in pulse and blood pressure in both the group. None or only slight discomfort was experienced by 9.4% in non sedated group and 90.6% in sedated group. Severe discomfort by 96.4% in non sedated group and 3.6% in sedated group.

CONCLUSIONS

There is slight more incidence of mild hypoxia in sedated group than in non sedated group but no change in pulse and blood pressure. However, sedated patient have significant less level of discomfort than in non sedated group. Though routine use of pulse oxymeter is not necessary, routine use of sedation during endoscopy is recommended.

摘要

相似文献

1
The role of sedation and pulse oximetry during upper gastrointestinal endoscopy.
JNMA J Nepal Med Assoc. 2009 Apr-Jun;48(174):92-8.
2
Hypoxia during upper gastrointestinal endoscopy with and without sedation and the effect of pre-oxygenation on oxygen saturation.上消化道内镜检查时有无镇静情况下的低氧血症以及预给氧对血氧饱和度的影响。
Anaesthesia. 2000 Jul;55(7):654-8. doi: 10.1046/j.1365-2044.2000.01520.x.
3
Pulse oximetry during gastrointestinal endoscopic procedures.胃肠道内镜检查期间的脉搏血氧饱和度测定法。
J Coll Physicians Surg Pak. 2006 Feb;16(2):97-100.
4
Arterial oxygen saturation in sedated patients undergoing gastrointestinal endoscopy and a review of pulse oximetry.
Del Med J. 1989 Oct;61(10):533-42.
5
Cardiorespiratory compromise under conscious sedation during upper gastrointestinal endoscopy.上消化道内镜检查期间清醒镇静下的心肺功能不全
J Coll Physicians Surg Pak. 2006 Sep;16(9):585-9.
6
Microstream capnography improves patient monitoring during moderate sedation: a randomized, controlled trial.微流二氧化碳监测技术改善了中度镇静期间的患者监测:一项随机对照试验。
Pediatrics. 2006 Jun;117(6):e1170-8. doi: 10.1542/peds.2005-1709. Epub 2006 May 15.
7
Supplemental oxygen during moderate sedation and the occurrence of clinically significant desaturation during endoscopic procedures.中度镇静期间的补充氧气与内镜检查过程中具有临床意义的血氧饱和度降低的发生情况。
Gastroenterol Nurs. 2008 Jul-Aug;31(4):281-5. doi: 10.1097/01.SGA.0000334034.94370.bf.
8
Changes in pulse oximetry levels and factors affecting oxygen saturation during routine upper gastrointestinal endoscopy with or without sedation.在有或没有镇静的常规上消化道内镜检查期间脉搏血氧饱和度水平的变化及影响氧饱和度的因素。
Turk J Gastroenterol. 2006 Dec;17(4):279-82.
9
[Patient Monitoring and Associated Devices during Endoscopic Sedation].[内镜镇静期间的患者监测及相关设备]
Korean J Gastroenterol. 2017 Jan 25;69(1):64-67. doi: 10.4166/kjg.2017.69.1.64.
10
Does pulse oximetry accurately monitor a patient's ventilation during sedated endoscopy under oxygen supplementation?脉搏血氧仪在氧补充镇静内镜检查期间能否准确监测患者的通气情况?
Singapore Med J. 2013 Apr;54(4):212-5. doi: 10.11622/smedj.2013075.