To investigate the settings for the optimal microwave ablation geometry with the simultaneous application of double 915 MHz antennae in ex vivo bovine livers, so as to provide the technical basis for treating large liver tumor in one ablation session.
MWAs were performed on ex vivo bovine livers by simultaneously application of double 915 MHz internally cooled-shaft antennae. Four power settings (50, 60, 70 and 80 W) were used during MWAs, while application time was fixed at 10 min. Three inter-antenna distances (2.0, 2.5 and 3.0 cm) were used. Diameters and shapes of the coagulation zones were observed on gross specimens.
(1) The coagulation shape was related to the inter-antenna distance, which was most spherical at an inter-antenna distance of 2.0 cm. A recess of the coagulation zone was observed at an inter-antenna distances of 2.5 and 3.0 cm. (2) The long-axis and short-axis coagulation diameter enlarged with increasing power output. However, there were no significant differences in the coagulation diameters between 70 and 80 W (P>0.05). More desirable coagulation geometry could be obtained by simultaneous application of double antennae at 70 W for 10 min with an inter-antenna distance of 2.0 cm, the long-axis and short-axis coagulation diameter were 6.95 ± 0.32 cm and 5.30 ± 0.22 cm, respectively.
Simultaneous application of double 915 MHz antennae can generate large coagulation zones with desirable shape which may be advantageous for treating large liver tumor in one ablation session.
研究在离体牛肝中同时应用双 915MHz 天线进行微波消融(MWA)的最佳消融几何形状的设置,为单次消融治疗大肝癌提供技术基础。
离体牛肝中同时应用双 915MHz 内部冷却轴天线进行 MWA。MWA 时使用 4 种功率设置(50、60、70 和 80W),应用时间固定为 10min。使用 3 种天线间距离(2.0、2.5 和 3.0cm)。在大体标本上观察凝固区的直径和形状。
(1)凝固形状与天线间距离有关,天线间距离为 2.0cm 时呈最球形。在天线间距离为 2.5 和 3.0cm 时观察到凝固区的凹陷。(2)长轴和短轴凝固直径随功率输出的增加而增大。然而,在 70 和 80W 之间,凝固直径没有显著差异(P>0.05)。通过在 70W 下 10min 同时应用双天线,天线间距离为 2.0cm,可获得更理想的凝固几何形状,长轴和短轴凝固直径分别为 6.95±0.32cm 和 5.30±0.22cm。