Suppr超能文献

比较视神经头图(NHM4)和频域光相干断层扫描(RTVue-100)的 RNFL3.45 模式计算的视网膜神经纤维层厚度测量值。

Comparison of retinal nerve fibre layer thickness measurements calculated by the optic nerve head map (NHM4) and RNFL3.45 modes of spectral-domain optical coherence tomography (RTVue-100).

机构信息

Department of Ophthalmology, University of Ulsan, College of Medicine, Asan Medical Center, Seoul, Korea.

出版信息

Br J Ophthalmol. 2010 Jun;94(6):763-7. doi: 10.1136/bjo.2009.166314.

Abstract

AIM

To evaluate and compare retinal nerve fibre layer (RNFL) thickness measured by direct scanning (RNFL3.45 mode) and re-sampling from datasets (NHM4 mode) of RTVue-100 optical coherence tomography (OCT).

METHODS

Thirty-six healthy subjects and 76 subjects with glaucoma were imaged with Stratus OCT (fast RNFL mode, RNFL3) and RTVue-100 OCT (NHM4 (RNFL1) and RNFL3.45 (RNFL2) modes). Measurement reproducibility was assessed in NHM4 and RNFL3.45 modes of RTVue-100 OCT (intraclass correlation coefficient (ICC)). Agreement between different RNFL measurements was analysed by Bland-Altman plot. The areas under the receiver operating characteristic (ROC) curves (AUCs) for discrimination between healthy and glaucoma were compared between the different RNFL measurements.

RESULTS

Both NHM4 and RNFL3.45 modes showed excellent measurement reproducibilities (ICC 0.831-0.978). RNFL thicknesses by two different modes of the RTVue-100 OCT, and by the Stratus OCT, were correlated in all sectors, including average. There was no significant difference between RNFL1 and RNFL2 data. However, RNFL thickness in glaucomatous eyes by the RTVue-100 OCT was significantly greater than that measured by Stratus OCT. RNFL thicknesses determined by the two different modes of RTVue-100 OCT were in excellent agreement (95% limits of agreement -6.53 to 6.95 mum). All three RNFL measurements showed good glaucoma discrimination ability (AUC = RNFL1 0.970, RNFL2 0.962, RNFL3 0.971).

CONCLUSIONS

RNFL thickness determined by direct scanning and re-sampling from datasets of RTVue-100 OCT were in good agreement. However, both measurements in glaucomatous subjects were significantly different from those with the Stratus OCT. Those findings should be considered when a patient is followed-up using different types of OCT.

摘要

目的

评估和比较视网膜神经纤维层(RNFL)厚度由直接扫描(RNFL3.45 模式)和从数据集重新采样(NHM4 模式)的 RTVue-100 光学相干断层扫描(OCT)测量的结果。

方法

对 36 名健康受试者和 76 名青光眼患者进行 Stratus OCT(快速 RNFL 模式,RNFL3)和 RTVue-100 OCT(NHM4(RNFL1)和 RNFL3.45(RNFL2)模式)成像。评估 RTVue-100 OCT 的 NHM4 和 RNFL3.45 模式的测量可重复性(组内相关系数(ICC))。通过 Bland-Altman 图分析不同 RNFL 测量值之间的一致性。比较不同 RNFL 测量值在健康和青光眼之间的鉴别诊断的受试者工作特征(ROC)曲线下面积(AUC)。

结果

NHM4 和 RNFL3.45 模式均表现出极好的测量可重复性(ICC 0.831-0.978)。RTVue-100 OCT 的两种不同模式和 Stratus OCT 的 RNFL 厚度在所有区域均相关,包括平均值。RNFL1 和 RNFL2 数据之间没有显著差异。然而,RTVue-100 OCT 测量的青光眼患者的 RNFL 厚度明显大于 Stratus OCT 测量的厚度。RTVue-100 OCT 的两种不同模式确定的 RNFL 厚度具有极好的一致性(95%一致性界限-6.53 至 6.95 μm)。所有三种 RNFL 测量均具有良好的青光眼鉴别能力(AUC=RNFL1 0.970,RNFL2 0.962,RNFL3 0.971)。

结论

RTVue-100 OCT 的直接扫描和从数据集重新采样确定的 RNFL 厚度具有良好的一致性。然而,在青光眼患者中,这两种测量值均与 Stratus OCT 明显不同。在使用不同类型的 OCT 对患者进行随访时,应考虑这些发现。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验