使用矢状面投影的锥形束计算机断层扫描头影测量与传统二维头影测量的比较。

Comparison of cone-beam computed tomography cephalometric measurements using a midsagittal projection and conventional two-dimensional cephalometric measurements.

作者信息

Jung Pil-Kyo, Lee Gung-Chol, Moon Cheol-Hyun

机构信息

Department of Orthodontics, Gachon University Gil Medical Center, Incheon, Korea.

出版信息

Korean J Orthod. 2015 Nov;45(6):282-8. doi: 10.4041/kjod.2015.45.6.282. Epub 2015 Nov 20.

Abstract

OBJECTIVE

This study investigated whether it is possible to use a two-dimensional (2D) standard in three-dimensional (3D) analysis, by comparing the angles and lengths measured from a midsagittal projection in 3D cone-beam computed tomography (CBCT) with those measured by 2D lateral cephalometric radiography (LCR).

METHODS

Fifty patients who underwent both LCR and CBCT were selected as subjects. CBCT was reoriented in 3 different methods and the measuring-points were projected onto the midsagittal plane. Twelve angle values and 8 length values were measured on both LCR and CBCT and compared.

RESULTS

Repeated measures analysis of the variance revealed statistically significant differences in 7 angular and 5 linear measurements among LCR and 3 types of CBCT (p < 0.05). Of these 12 measurements, multiple comparisons showed that 6 measurements (ANB, AB to FH, IMPA, FMA, Co-Gn, Go-Me) were not significantly different in pairwise comparisons. LCR was significantly different from 3 types of CBCT in 3 angular (SN to FH, interincisal angle, FMIA) and 2 linear (S-Go, Co-ANS) measurements. The CBCT method was similar for all measurements, except for 1 linear measurement, i.e., S-N. However, the disparity between the mean values for all parameters was within the range of clinical measurement error.

CONCLUSIONS

3D-CBCT analysis, using midsagittal projection, is a useful method in which the 2D-LCR normative values can be used. Although the measurements changed with reorientation, these changes were not clinically significant.

摘要

目的

本研究通过比较三维锥形束计算机断层扫描(CBCT)矢状面投影测量的角度和长度与二维头颅侧位X线摄影(LCR)测量的角度和长度,探讨在三维分析中使用二维标准的可能性。

方法

选取50例同时接受LCR和CBCT检查的患者作为研究对象。CBCT以3种不同方法重新定位,测量点投影到矢状面上。在LCR和CBCT上测量12个角度值和8个长度值并进行比较。

结果

重复测量方差分析显示,LCR与3种类型的CBCT在7个角度测量值和5个线性测量值上存在统计学显著差异(p<0.05)。在这12项测量中,多重比较显示,6项测量值(ANB、AB与FH、IMPA、FMA、Co-Gn、Go-Me)在两两比较中无显著差异。LCR与3种类型的CBCT在3个角度测量值(SN与FH、切牙间角、FMIA)和2个线性测量值(S-Go、Co-ANS)上存在显著差异。除1个线性测量值即S-N外,CBCT的所有测量方法相似。然而,所有参数平均值之间的差异在临床测量误差范围内。

结论

使用矢状面投影的三维CBCT分析是一种有用的方法,可使用二维LCR标准值。尽管测量值随重新定位而变化,但这些变化在临床上并不显著。