PURPOSE

To examine the effect of astigmatism on visual acuity at various distances in eyes with a diffractive multifocal intraocular lens (IOL).

SETTING

Hayashi Eye Hospital, Fukuoka, Japan.

METHODS

In this study, eyes had implantation of a diffractive multifocal IOL with a +3.00 diopter (D) addition (add) (AcrySof ReSTOR SN6AD1), a diffractive multifocal IOL with a +4.00 D add (AcrySof ReSTOR SN6AD3), or a monofocal IOL (AcrySof SN60WF). Astigmatism was simulated by adding cylindrical lenses of various diopters (0.00, 0.50, 1.00, 1.50, 2.00), after which distance-corrected acuity was measured at various distances.

RESULTS

At most distances, the mean visual acuity in the multifocal IOL groups decreased in proportion to the added astigmatism. With astigmatism of 0.00 D and 0.50 D, distance-corrected near visual acuity (DCNVA) in the +4.00 D group and distance-corrected intermediate visual acuity (DCIVA) and DCNVA in the +3.00 D group were significantly better than in the monofocal group; the corrected distance visual acuity (CDVA) was similar. The DCNVA with astigmatism of 1.00 D was better in 2 multifocal groups; however, with astigmatism of 1.50 D and 2.00 D, the CDVA and DCIVA at 0.5m in the multifocal groups were significantly worse than in the monofocal group, although the DCNVA was similar. With astigmatism of 1.00 D or greater, the mean CDVA and DCNVA in the multifocal groups reached useful levels (20/40).

CONCLUSION

The presence of astigmatism in eyes with a diffractive multifocal IOL compromised all distance visual acuities, suggesting the need to correct astigmatism of greater than 1.00 D.

FINANCIAL DISCLOSURE

No author has a financial or proprietary interest in any material or method mentioned.

摘要

目的

研究散光对植入衍射型多焦点人工晶状体(IOL)后不同距离视力的影响。

设置

日本福冈市林眼科医院。

方法

本研究中,通过添加不同屈光度(0、0.5、1.0、1.5、2.0 )的圆柱镜模拟散光,对植入+3.00 D(附加)(AcrySof ReSTOR SN6AD1)、+4.00 D(附加)(AcrySof ReSTOR SN6AD3)衍射型多焦点 IOL 或单焦点 IOL(AcrySof SN60WF)的眼进行研究,然后在不同距离测量距离矫正视力。

结果

在大多数距离,多焦点 IOL 组的平均视力随附加散光的增加而降低。散光为 0.00 D 和 0.50 D 时,+4.00 D 组的距离校正近视力(DCNVA)和+3.00 D 组的距离校正中间视力(DCIVA)和 DCNVA 显著优于单焦点组,校正距离视力(CDVA)相似。在 2 个多焦点组中,散光为 1.00 D 时 DCNVA 更好;然而,散光为 1.50 D 和 2.00 D 时,多焦点组在 0.5m 时的 CDVA 和 DCIVA 显著低于单焦点组,尽管 DCNVA 相似。散光为 1.00 D 或更大时,多焦点组的平均 CDVA 和 DCNVA 达到有用水平(20/40)。

结论

在植入衍射型多焦点 IOL 的眼中存在散光会影响所有距离的视力,这表明需要矫正大于 1.00 D 的散光。