Suppr超能文献

采用尼德克 OPD-Scan 评估植入非球面和球面人工晶状体的眼的光学质量:一项随机、双侧、临床试验。

Optical quality in eyes implanted with aspheric and spherical intraocular lenses assessed by NIDEK OPD-Scan: a randomized, bilateral, clinical trial.

机构信息

Ophthalmology Department, University of São Paulo, Brazil.

出版信息

J Refract Surg. 2011 Apr;27(4):287-92. doi: 10.3928/1081597X-20100714-01. Epub 2010 Jul 15.

Abstract

PURPOSE

To determine whether implantation of an intraocular lens (IOL) with an aspheric surface (Akreos AO, Bausch & Lomb Inc) results in reduced ocular aberrations (spherical aberration) and improved Strehl ratio and modulation transfer function (MTF) after cataract surgery.

METHODS

In an intraindividual, randomized, double-masked, prospective study of 50 eyes (25 patients) with bilateral cataract, an IOL with modified anterior and posterior surfaces (Akreos AO) was implanted in one eye and a biconvex IOL with spherical surfaces (Akreos Fit, Bausch & Lomb Inc) implanted in the fellow eye. Ocular aberrations, Strehl ratio, and MTF curve with 4.5-, 5.0-, and 6.0-mm pupils were measured with a NIDEK OPD-Scan dynamic retinoscopy aberrometer 3 months after surgery. Uncorrected and corrected distance visual acuity (UDVA and CDVA, respectively) were also measured.

RESULTS

No statistically significant difference was noted between eyes in postoperative UDVA and CDVA at 1 month. At 3 months, the Akreos AO IOL group obtained statistically significant lower values of higher order and spherical aberrations with 4.5-, 5.0-, and 6.0-mm pupil diameters than the Akreos Fit IOL group (P<.05). The value of Strehl ratio was statistically significantly higher in eyes with the Akreos AO IOL for 4.5- and 6.0-mm pupils (P<.05). The MTF curve was better in the Akreos AO IOL group in 4.5-, 5.0-, and 6.0-mm pupils (P<.05).

CONCLUSIONS

The aspheric Akreos AO IOL induced significantly less spherical aberration than the Akreos Fit IOL for 4.5-, 5.0-, and 6.0-mm pupils. Modulation transfer function and Strehl ratio were also better in eyes implanted with the Akreos AO IOL than the Akreos Fit.

摘要

目的

确定植入具有非球面表面(Akreos AO,Bausch & Lomb Inc)的人工晶状体(IOL)是否会减少白内障手术后的眼像差(球差)并提高斯特列尔比和调制传递函数(MTF)。

方法

在一项针对 50 只眼(25 例患者)的双眼白内障的个体内、随机、双盲、前瞻性研究中,一只眼植入具有改良前后表面的 IOL(Akreos AO),另一只眼植入具有球面的双凸 IOL(Akreos Fit,Bausch & Lomb Inc)。术后 3 个月,使用 NIDEK OPD-Scan 动态视网膜验光仪测量眼像差、斯特列尔比和 4.5、5.0 和 6.0mm 瞳孔的 MTF 曲线。还测量了未矫正和矫正远视力(UDVA 和 CDVA,分别)。

结果

术后 1 个月,双眼 UDVA 和 CDVA 无统计学差异。术后 3 个月,Akreos AO IOL 组与 Akreos Fit IOL 组相比,4.5、5.0 和 6.0mm 瞳孔直径的高阶像差和球差的测量值明显较低(P<.05)。Akreos AO IOL 组 4.5 和 6.0mm 瞳孔的斯特列尔比明显较高(P<.05)。Akreos AO IOL 组在 4.5、5.0 和 6.0mm 瞳孔时的 MTF 曲线更好(P<.05)。

结论

与 Akreos Fit IOL 相比,Akreos AO 非球面 IOL 在 4.5、5.0 和 6.0mm 瞳孔时引起的球差明显更小。植入 Akreos AO IOL 的眼的调制传递函数和斯特列尔比也优于 Akreos Fit IOL。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验