Thirty-two patients who had been treated with 71 computer-aided design/computer-assisted manufacture-fabricated Cercon crowns were followed to assess clinical performance by time-to-event analysis. Clinical examinations consisted of a complete dental and oral hygiene examination and a quality assessment by modified California Dental Association criteria. Four patients (6 crowns) were lost to follow-up; another 11 crowns had to be excluded from evaluation for comparability reasons. Six of 54 evaluated crowns experienced complications (P(C) = 11.1%) throughout a mean observation time of 21 months. Survival was estimated at 0.98 over 24 months. The good overall clinical performance was affected predominantly by technical complications of the veneering ceramic (P(TC) = 9.3%).
32 名患者接受了 71 个计算机辅助设计/计算机辅助制造制作的 Cercon 牙冠治疗,通过事件时间分析来评估临床效果。临床检查包括完整的口腔和口腔卫生检查以及根据改良加州牙科协会标准进行的质量评估。4 名患者(6 个牙冠)失访;另有 11 个牙冠因可比性原因被排除在评估之外。54 个评估牙冠中有 6 个(P(C) = 11.1%)在平均 21 个月的观察期内出现并发症。24 个月时的生存率估计为 0.98。整体良好的临床效果主要受到贴面陶瓷的技术并发症(P(TC) = 9.3%)的影响。