Department Orthopedic Surgery, George Washington University,Washington, DC, USA.
J Arthroplasty. 2011 Sep;26(6):855-60. doi: 10.1016/j.arth.2010.08.017. Epub 2010 Oct 29.
The use of Trabecular Metal (TM), a biomaterial manufactured from elemental tantalum metal, has recently increased in orthopedics. One hundred eight consecutive TM monoblock tibias were implanted in 95 patients and followed for a minimum of 2 years. The average follow-up was 4.5 years. The average age was 65 years. The Knee Society score of 36 improved to 89. One hundred five of the knees were rated good/excellent, and 3 knees were rated poor. Two patellar revisions were performed for loose components and one for patellar misalignment. One patella fracture required open reduction and internal fixation. One femur was revised. There were no tibia revisions. There were no progressive radiographic lucencies. Midterm clinical and radiographic results of 108 consecutive TM tibia components have a high rate of success.
最近,在骨科领域,一种由元素钽金属制造的生物材料——小梁金属(TM)的使用有所增加。95 名患者共植入了 108 个 TM 一体式胫骨,并进行了至少 2 年的随访。平均随访时间为 4.5 年。平均年龄为 65 岁。膝关节协会评分从 36 分提高到了 89 分。105 个膝关节被评为良好/优秀,3 个膝关节被评为差。2 个髌骨进行了翻修以处理松动的组件,1 个髌骨进行了矫正。1 个髌骨骨折需要切开复位和内固定。1 个股骨进行了翻修。没有胫骨翻修。没有进行进一步的放射学透亮线检查。108 例连续 TM 胫骨组件的中期临床和放射学结果显示成功率很高。