Suppr超能文献

树脂基水门汀黏结剂转化率的临界分析。

A critical analysis of the degree of conversion of resin-based luting cements.

机构信息

Department of Restorative Dentistry, School of Dentistry, Federal Fluminense University, Niterói, RJ, Brazil.

出版信息

J Appl Oral Sci. 2010 Sep-Oct;18(5):442-6. doi: 10.1590/s1678-77572010000500003.

Abstract

OBJECTIVE

This study analyzed the degree of conversion (DC%) of four resin-based cements (All Ceram, Enforce, Rely X ARC and Variolink II) activated by two modes (chemical and dual), and evaluated the decrease of DC% in the dual mode promoted by the interposition of a 2.0-mm-thick IPS Empress 2 disc.

MATERIAL AND METHODS

In the chemical activation, the resin-based cements were prepared by mixing equal amounts of base and catalyst pastes. In the dual activation, after mixing, the cements were light-activated at 650 mW/cm² for 40 s. In a third group, the cements were light-activated through a 2.0-mm-thick IPS Empress 2 disc. The DC% was evaluated in a FT-IR spectrometer equipped with an attenuated total reflectance crystal (ATR). The data were analyzed by two-way ANOVA and Tukey's HSD test.

RESULTS

For all resin-based cements, the DC% was significantly higher with dual activation, followed by dual activation through IPS Empress 2, and chemical activation (p<0.05). Irrespective of the activation mode, Rely X presented the highest DC% (p<0.05). Chemically activated Variolink and All Ceram showed the worst results (p<0.05). The DC% decreased significantly when activation was performed through a 2.0-mm-thick IPS Empress 2 disc (p<0.05).

CONCLUSION

The results of the present study suggest that resin-based cements could present low DC% when the materials are dually activated through 2.0 mm of reinforced ceramic materials with translucency equal to or less than that of IPS-Empress 2.

摘要

目的

本研究分析了四种树脂基水泥(All Ceram、Enforce、Rely X ARC 和 Variolink II)在两种激活模式(化学和双重)下的转化率(DC%),并评估了在插入 2.0 毫米厚 IPS Empress 2 圆盘的双重模式下 DC%的降低程度。

材料和方法

在化学激活中,将等量的基础糊剂和催化剂糊剂混合制备树脂基水泥。在双重激活中,混合后,将水泥在 650 mW/cm² 下光激活 40 秒。在第三组中,通过 2.0 毫米厚的 IPS Empress 2 圆盘进行光激活。使用配备衰减全反射晶体(ATR)的 FT-IR 光谱仪评估 DC%。使用双向方差分析和 Tukey 的 HSD 检验对数据进行分析。

结果

对于所有树脂基水泥,双重激活的 DC%明显更高,其次是通过 IPS Empress 2 的双重激活,然后是化学激活(p<0.05)。无论激活模式如何,Rely X 均表现出最高的 DC%(p<0.05)。化学激活的 Variolink 和 All Ceram 表现出最差的结果(p<0.05)。当通过 2.0 毫米厚的 IPS Empress 2 圆盘进行激活时,DC%显着降低(p<0.05)。

结论

本研究结果表明,当通过具有与 IPS-Empress 2 相等或更低透光率的 2.0 毫米增强陶瓷材料双重激活时,树脂基水泥的 DC%可能会较低。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/20e3/4246373/8a42d658c9f3/jaos-18-05-0442-g01.jpg

相似文献

1
A critical analysis of the degree of conversion of resin-based luting cements.
J Appl Oral Sci. 2010 Sep-Oct;18(5):442-6. doi: 10.1590/s1678-77572010000500003.
2
Degree of conversion and bond strength of resin-cements to feldspathic ceramic using different curing modes.
J Appl Oral Sci. 2017 Jan-Feb;25(1):61-68. doi: 10.1590/1678-77572016-0221.
5
Effect of curing mode on the micro-mechanical properties of dual-cured self-adhesive resin cements.
Clin Oral Investig. 2012 Apr;16(2):505-12. doi: 10.1007/s00784-011-0527-x. Epub 2011 Feb 25.
8
Pre-heated dual-cured resin cements: analysis of the degree of conversion and ultimate tensile strength.
Braz Oral Res. 2011 Mar-Apr;25(2):174-9. doi: 10.1590/s1806-83242011000200013.
10
Influence of different ceramics on resin cement Knoop Hardness Number.
Oper Dent. 2008 Nov-Dec;33(6):622-8. doi: 10.2341/07-155.

引用本文的文献

2
Degree of conversion and microhardness of resin cements photoactivated through glass ceramic.
J Clin Exp Dent. 2021 Nov 1;13(11):e1068-e1075. doi: 10.4317/jced.58630. eCollection 2021 Nov.
4
Degree of Conversion of Resin-Modified Glass Ionomer Cement Containing Hydroxyapatite Nanoparticles.
Front Dent. 2019 Nov-Dec;16(6):415-420. doi: 10.18502/fid.v16i6.3440. Epub 2019 Dec 20.
6
Effect of various polymerization protocols on the cytotoxicity of conventional and self-adhesive resin-based luting cements.
Clin Oral Investig. 2020 Mar;24(3):1161-1170. doi: 10.1007/s00784-019-02980-3. Epub 2019 Jul 20.
7
Influence of curing protocol and ceramic composition on the degree of conversion of resin cement.
J Appl Oral Sci. 2017 Nov-Dec;25(6):700-707. doi: 10.1590/1678-7757-2016-0270.
8
Curing efficiency of dual-cure resin cement under zirconia with two different light curing units.
J Istanb Univ Fac Dent. 2015 Apr 29;49(2):8-16. doi: 10.17096/jiufd.97059. eCollection 2015.
9
Can cement film thickness influence bond strength and fracture resistance of fiber reinforced composite posts?
Clin Oral Investig. 2016 May;20(4):849-55. doi: 10.1007/s00784-015-1568-3. Epub 2015 Aug 29.

本文引用的文献

1
Polymerization of a dual-cured cement through ceramic: LED curing light vs halogen lamp.
J Appl Oral Sci. 2004 Dec;12(4):312-6. doi: 10.1590/s1678-77572004000400011.
3
Effect of light-curing units, post-cured time and shade of resin cement on knoop hardness.
Braz Dent J. 2009;20(5):410-3. doi: 10.1590/s0103-64402009000500009.
4
Glass transition and degree of conversion of a light-cured orthodontic composite.
J Appl Oral Sci. 2009 Nov-Dec;17(6):570-3. doi: 10.1590/s1678-77572009000600006.
5
Infrared spectroscopy: a tool for determination of the degree of conversion in dental composites.
J Appl Oral Sci. 2008 Mar-Apr;16(2):145-9. doi: 10.1590/s1678-77572008000200012.
7
Customization of milled zirconia copings for all-ceramic crowns: a clinical report.
J Prosthet Dent. 2008 Mar;99(3):169-73. doi: 10.1016/S0022-3913(08)00028-0.
8
Correlation between ceramics translucency and polymerization efficiency through ceramics.
Dent Mater. 2008 Jul;24(7):908-14. doi: 10.1016/j.dental.2007.11.006. Epub 2008 Feb 21.
9
Solubility, salivary sorption and degree of conversion of dimethacrylate-based polymeric matrixes.
J Biomed Mater Res B Appl Biomater. 2008 May;85(2):320-5. doi: 10.1002/jbm.b.30949.
10
Degree of conversion of dual-cure luting resins light-polymerized through various materials.
Acta Odontol Scand. 2007 Aug;65(4):201-5. doi: 10.1080/00016350701311632.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验