Suppr超能文献

前节光学相干断层扫描测量 LASIK 瓣:飞秒激光与微型角膜刀。

Anterior segment optical coherence tomography measurement of LASIK flaps: femtosecond laser vs microkeratome.

机构信息

Ophthalmic Center, Beijing Tongren Hospital, Capital Medical Univeristy, Beijing, China.

出版信息

J Refract Surg. 2011 Jun;27(6):408-16. doi: 10.3928/1081597X-20101029-01. Epub 2010 Nov 5.

Abstract

PURPOSE

To compare the uniformity and accuracy of LASIK flaps created with a femtosecond laser versus a mechanical microkeratome using optical coherence tomography (OCT).

METHODS

A prospective study was performed on 72 consecutive patients who underwent LASIK in both eyes in alternating fashion with either the AMO IntraLase FS60 (72 eyes) or the Moria M2 microkeratome (72 eyes). One month after surgery, anterior segment OCT was performed on each eye to measure flap thickness at 20 locations and the results were assessed for uniformity and accuracy.

RESULTS

At 1 month after surgery, the microkeratome group flap ranges were greater than those found in the femtosecond laser group (P<.05). The meridian and radial flap uniformity in the femtosecond laser group were better, showing an almost planar configuration, than the meniscus-shaped flaps created with the microkeratome. Comparison of the nasal and temporal flap thickness revealed more regularity in the femtosecond laser group than the microkeratome group. The maximum deviation from the intended flap thicknesses was 7 μm in the femtosecond laser group compared to 26 μm in the microkeratome group. During the 1440 measurements of the 72 eyes, a difference >20 μm was observed in 0.42% of eyes in the femtosecond laser group and 15% of eyes in the microkeratome group.

CONCLUSIONS

LASIK flaps made with the IntraLase FS60 were more uniform with more accurate thickness than those created by the Moria M2 microkeratome.

摘要

目的

使用光学相干断层扫描(OCT)比较飞秒激光与机械微型角膜刀制作的 LASIK 瓣的均匀性和准确性。

方法

前瞻性研究 72 例连续患者,双眼交替接受 AMO IntraLase FS60(72 眼)或 Moria M2 微型角膜刀(72 眼)行 LASIK。术后 1 个月,对每只眼进行眼前节 OCT 检查,测量 20 个位置的瓣厚度,并评估其均匀性和准确性。

结果

术后 1 个月,微型角膜刀组瓣范围大于飞秒激光组(P<.05)。飞秒激光组的子午线和放射状瓣均匀性较好,呈几乎平面状,而微型角膜刀组形成的瓣呈新月形。比较鼻侧和颞侧瓣厚度,飞秒激光组比微型角膜刀组更规则。飞秒激光组最大瓣厚度偏差为 7μm,而微型角膜刀组为 26μm。在对 72 只眼的 1440 次测量中,飞秒激光组有 0.42%的眼偏差>20μm,而微型角膜刀组有 15%的眼偏差>20μm。

结论

IntraLase FS60 制作的 LASIK 瓣比 Moria M2 微型角膜刀制作的更均匀,厚度更准确。