Abstract

Quantification of oversulfated chondroitin sulfate (OSCS) in biomedical heparin preparations is achieved using a recently described potentiometric polyanion sensor-based approach operated in a kinetic mode of analysis. This is accomplished by adjusting the concentration of the test sample to a range where the OSCS level is low enough for the sensor not to achieve a full and rapid equilibrium phase boundary potential change at the membrane/sample interface upon exposure to the heparin sample. Using this method, the OSCS wt% determined within heparin samples containing OSCS are shown to be in good agreement with those determined by an accepted NMR method.

摘要

使用最近描述的基于电位聚阴离子传感器的方法,以动力学分析模式实现生物医学肝素制剂中过硫酸化硫酸软骨素(OSCS)的定量。这是通过将测试样品的浓度调整到一个范围来实现的,在该范围内,OSCS水平足够低,以至于传感器在暴露于肝素样品时,在膜/样品界面不会实现完全且快速的平衡相界电位变化。使用这种方法,含有OSCS的肝素样品中测定的OSCS重量百分比与通过公认的核磁共振方法测定的结果高度一致。

相似文献

3
Reversible Electrochemical Sensor for Detection of High-Charge Density Polyanion Contaminants in Heparin.
Anal Chem. 2015 Nov 17;87(22):11537-43. doi: 10.1021/acs.analchem.5b03347. Epub 2015 Oct 28.
4
Highly sensitive potentiometric strip test for detecting high charge density impurities in heparin.
Anal Chem. 2011 May 15;83(10):3957-62. doi: 10.1021/ac103090m. Epub 2011 Apr 18.
5
Quantitative capillary electrophoresis determination of oversulfated chondroitin sulfate as a contaminant in heparin preparations.
Anal Biochem. 2009 May 1;388(1):140-5. doi: 10.1016/j.ab.2009.02.012. Epub 2009 Feb 14.
6
Determination of oversulfated chondroitin sulfate and dermatan sulfate impurities in heparin by capillary electrophoresis.
J Chromatogr A. 2009 May 1;1216(18):4107-12. doi: 10.1016/j.chroma.2009.02.063. Epub 2009 Feb 26.

引用本文的文献

1
Polyion selective polymeric membrane-based pulstrode as a detector in flow-injection analysis.
Anal Chem. 2014 Apr 15;86(8):4041-6. doi: 10.1021/ac500567g. Epub 2014 Apr 1.
2
Analysis and characterization of heparin impurities.
Anal Bioanal Chem. 2011 Jan;399(2):527-39. doi: 10.1007/s00216-010-4121-x. Epub 2010 Sep 3.

本文引用的文献

3
Quality assessment of unfractionated heparin using 1H nuclear magnetic resonance spectroscopy.
J Pharm Biomed Anal. 2008 Sep 10;48(1):13-9. doi: 10.1016/j.jpba.2008.06.014. Epub 2008 Jul 3.
4
Oversulfated chondroitin sulfate is a contaminant in heparin associated with adverse clinical events.
Nat Biotechnol. 2008 Jun;26(6):669-75. doi: 10.1038/nbt1407. Epub 2008 Apr 23.
5
Contaminated heparin associated with adverse clinical events and activation of the contact system.
N Engl J Med. 2008 Jun 5;358(23):2457-67. doi: 10.1056/NEJMoa0803200. Epub 2008 Apr 23.
7
Essentials of anticoagulation in hemodialysis.
Hemodial Int. 2007 Apr;11(2):178-89. doi: 10.1111/j.1542-4758.2007.00166.x.
8
Heparin-protein interactions.
Angew Chem Int Ed Engl. 2002 Feb 1;41(3):391-412. doi: 10.1002/1521-3773(20020201)41:3<390::aid-anie390>3.0.co;2-b.
10
Conformational changes and anticoagulant activity of chondroitin sulfate following its O-sulfonation.
Carbohydr Res. 1998 Jan;306(1-2):35-43. doi: 10.1016/s0008-6215(97)10060-x.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验