Suppr超能文献

The oxygen status of the arterial blood revised: relevant oxygen parameters for monitoring the arterial oxygen availability.

作者信息

Siggaard-Andersen O, Gøthgen I H, Wimberley P D, Fogh-Andersen N

机构信息

Department of Clinical Chemistry, Herlev Hospital, Denmark.

出版信息

Scand J Clin Lab Invest Suppl. 1990;203:17-28. doi: 10.3109/00365519009087488.

Abstract

The new generation of very accurate multi-wavelength oximeters, e.g. OSM3, for in vitro measurement of the hemoglobin oxygen saturation, total hemoglobin concentration, and carboxy- and methemoglobin fractions opens new aspects of oxygen monitoring. Combined with the data from the blood gas analyzer (e.g. ABL300) these very accurate measurements allow the calculation of several derived oxygen parameters on the basis of a set of newly developed calculation algorithms. The traditional parameters obtained from an arterial sample are the oxygen tension (pO2) and the hemoglobin oxygen saturation (sO2). Clinical examples illustrate that the pO2 and the sO2 even in combination may give misleading information. The new algorithm calculates three extra oxygen parameters. 1) The oxygen extraction tension, px, defined as the tension required to extract 2.3 mmol of oxygen per liter blood. It signals the mixed venous pO2 level on the assumption that the arterio-venous oxygen difference is normal (2.3 mmol/L). 2) The concentration of extractable oxygen, cx, defined as the concentration of oxygen extracted at a tension of 5.0 kPa. 3) The oxygen compensation factor, Qx, derived as (2.3 mmol/L)/cx. It may be interpreted as the increase in cardiac output necessary to maintain a normal mixed venous pO2 of 5 kPa. These three parameters indicate the oxygen availability of the blood and summarize important properties of the arterial blood in relation to oxygen supply of the tissues, including the arterial pO2, the 'active' hemoglobin concentration (equivalent to the oxygen capacity), and the hemoglobin oxygen affinity (p50). The set of data measured with the blood gas analyzer, e.g. the ABL300 combined with the data measured with the OSM3 contains much more information than is routinely utilized. This information is extracted and summarized by our calculation algorithm. Omitting the calculation of the extra oxygen parameters involves a risk of losing valuable information.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验