Suppr超能文献

通过一种快速而简单的电化学方法制备的纳米多孔金膜电极上葡萄糖的非酶安培响应。

Nonenzymatic amperometric response of glucose on a nanoporous gold film electrode fabricated by a rapid and simple electrochemical method.

机构信息

Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Ministry of Education of China), College of Chemistry and Chemical Engineering, Hunan Normal University, Lushan Road, ChangSha, Hunan 410081, China.

出版信息

Biosens Bioelectron. 2011 Apr 15;26(8):3555-61. doi: 10.1016/j.bios.2011.01.044. Epub 2011 Feb 26.

Abstract

An enzyme-free amperometric method was established for glucose detection using a nanoporous gold film (NPGF) electrode prepared by a rapid one-step anodic potential step method within 5 min. The prepared NPGF had an extremely high roughness and was characterized by scanning electron microscopy (SEM) and cyclic voltammetry. Electrochemical responses of the as-prepared NPGF to glucose in 0.1M phosphate buffer solution (PBS, pH 7.4) with or without Cl(-) were discussed. In amperometric studies carried out at -0.15 V in the absence of Cl(-), the NPGF electrode exhibited a high sensitivity of 232 μA mM(-1)cm(-2) and gave a linear range from 1mM up to 14 mM with a detection limit of 53.2 μM (with a signal-to-noise ratio of 3). In addition, the oxidation of ascorbic acid (AA) and uric acid (UA) can be completely eliminated at such a low applied potential. On the other hand, the quantification of glucose in 0.1M PBS (pH 7.4) containing 0.1M NaCl offered an extended linear range from 10 μM to 11 mM with a sensitivity of 66.0 μA mM(-1)cm(-2) and a low detection limit of 8.7 μM (signal-to-noise ratio of 3) at a detection potential of 0.2V.

摘要

一种无酶的安培法被建立用于葡萄糖检测,使用一种通过快速一步阳极电势阶跃法在 5 分钟内制备的纳米多孔金膜(NPGF)电极。所制备的 NPGF 具有极高的粗糙度,并通过扫描电子显微镜(SEM)和循环伏安法进行了表征。讨论了在没有 Cl(-)的情况下,在 0.1M 磷酸盐缓冲溶液(PBS,pH 7.4)中,制备的 NPGF 对葡萄糖的电化学响应。在没有 Cl(-)的情况下,在 -0.15 V 进行的安培研究中,NPGF 电极表现出 232 μA mM(-1)cm(-2)的高灵敏度,并给出了从 1mM 到 14 mM 的线性范围,检测限为 53.2 μM(信噪比为 3)。此外,在如此低的应用电势下,可以完全消除抗坏血酸(AA)和尿酸(UA)的氧化。另一方面,在含有 0.1M NaCl 的 0.1M PBS(pH 7.4)中定量葡萄糖提供了从 10 μM 到 11 mM 的扩展线性范围,灵敏度为 66.0 μA mM(-1)cm(-2),检测限为 8.7 μM(信噪比为 3),检测电势为 0.2V。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验