Int J Cardiovasc Imaging. 2012 Mar;28(3):603-11. doi: 10.1007/s10554-011-9828-z. Epub 2011 Feb 26.
To compare the measurement of global left-ventricular (LV) function parameters of 64-slice multidetector-row computed tomography (MDCT) between 20- and 10-reconstruction phases. Fifty five patients with suspected or known coronary artery disease underwent 64-slice MDCT. LV end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and ejection fraction (EF) were measured from MDCT data sets using threshold-based volume segmentation and reconstruction at every 5% (20 phases) and 10% (10 phases) step through the R-R interval. These global functional parameters were compared to those obtained via two-dimensional transthoracic echocardiography (2D-TTE), considering the reference standard. The required time for CT data analysis was checked. Agreement for parameters of LV global function was determined using Pearson's correlation coefficient (r) and Bland-Altman analysis. LV volumes (EDV(-5%) 87.5 ± 17.1 ml, EDV(-10%) 87.7 ± 16.3 ml; ESV(-5%) 32.4 ± 10.6 ml, ESV(-10%) 31.9 ± 9.9 ml; SV(-5%) 55.1 ± 10.5 ml, SV(-10%) 55.8 ± 9.9 ml; mean ± SD) and EF (EF(-5%) 63.4 ± 6.2%, EF(-10%) 63.9 ± 5.8%) did not differ significantly between the 20- and 10 phase reconstructions, and evidenced good to excellent correlation (r = 0.786-0.896, all P < 0.001) with the 2D-TTE results. The mean required time for CT data analysis in the 20- and 10 phase reconstructions were 15.5 ± 4.0 and 7.3 ± 2.5 min. Within MDCT, using 10-phase image reconstruction is sufficient to evaluate LV volumes and EF, and is also more time-effective than 20-phase reconstruction.
比较 64 层多排螺旋 CT(MDCT)在 20 期和 10 期重建相位测量左心室(LV)功能参数的测量值。55 例疑诊或已知冠心病患者行 64 层 MDCT 检查。LV 舒张末期容积(EDV)、收缩末期容积(ESV)、每搏量(SV)和射血分数(EF)通过基于阈值的容积分割,在 R-R 间期的每 5%(20 期)和 10%(10 期)的步长进行 MDCT 数据采集。将这些全局功能参数与二维经胸超声心动图(2D-TTE)测量结果相比较,作为参考标准。检查 CT 数据分析所需的时间。使用 Pearson 相关系数(r)和 Bland-Altman 分析确定 LV 整体功能参数的一致性。LV 容积(EDV(-5%)87.5 ± 17.1 ml,EDV(-10%)87.7 ± 16.3 ml;ESV(-5%)32.4 ± 10.6 ml,ESV(-10%)31.9 ± 9.9 ml;SV(-5%)55.1 ± 10.5 ml,SV(-10%)55.8 ± 9.9 ml;平均值 ± 标准差)和 EF(EF(-5%)63.4 ± 6.2%,EF(-10%)63.9 ± 5.8%)在 20 期和 10 期重建中无明显差异,与 2D-TTE 结果具有良好至极好的相关性(r = 0.786-0.896,均 P < 0.001)。20 期和 10 期重建的 CT 数据分析平均所需时间分别为 15.5 ± 4.0 和 7.3 ± 2.5 min。在 MDCT 中,使用 10 期图像重建足以评估 LV 容积和 EF,并且比 20 期重建更节省时间。