Suppr超能文献

三维非依赖性平衡稳态自由进动管壁 MRI 技术在腘动脉中的应用:初步经验及与依赖性黑血技术的对比。

Three-dimensional flow-independent balanced steady-state free precession vessel wall MRI of the popliteal artery: preliminary experience and comparison with flow-dependent black-blood techniques.

机构信息

Department of Biomedical Engineering, Cornell University, Ithaca, New York, USA.

出版信息

J Magn Reson Imaging. 2011 Sep;34(3):696-701. doi: 10.1002/jmri.22663. Epub 2011 Jul 18.

Abstract

PURPOSE

To examine the feasibility of flow-independent T2-prepared inversion recovery (T2IR) black-blood (BB) magnetization preparation for three-dimensional (3D) balanced steady-state free precession (SSFP) vessel wall MRI of the popliteal artery, and to evaluate its performance relative to flow-dependent double inversion recovery (DIR), spatial presaturation (SPSAT), and motion-sensitizing magnetization preparation (MSPREP) BB techniques in healthy volunteers.

MATERIALS AND METHODS

Eleven subjects underwent 3D MRI at 1.5 Tesla with four techniques performed in a randomized order. Wall and lumen signal-to-noise ratio (SNR), wall-to-lumen contrast-to-noise ratio (CNR), vessel wall area, and lumen area were measured at proximal, middle, and distal locations of the imaged popliteal artery. Image quality scores based on wall visualization and degree of intraluminal artifacts were also obtained.

RESULTS

In the proximal region, DIR and SPSAT had higher wall SNR and wall-to-lumen CNR than both MSPREP and T2IR. In the middle and distal regions, DIR and SPSAT failed to provide effective blood suppression, whereas MSPREP and T2IR provided adequate black blood contrast with comparable wall-to-lumen CNR and image quality.

CONCLUSION

The feasibility of 3D SSFP imaging of the popliteal vessel wall using flow-independent T2IR was demonstrated with effective blood suppression and good vessel wall visualization. Although DIR and SPSAT are effective for thin slab imaging, MSPREP and T2IR are better suited for 3D thick slab imaging.

摘要

目的

探讨在三维(3D)平衡稳态自由进动(SSFP)血管壁 MRI 中应用非流相关 T2 预反转恢复(T2IR)黑血(BB)磁化准备技术的可行性,并评估其在健康志愿者中的性能,与流相关双反转恢复(DIR)、空间预饱和(SPSAT)和运动敏感磁化准备(MSPREP)BB 技术进行比较。

材料与方法

11 名受试者在 1.5T 磁共振仪上进行 3D MRI 检查,四种技术以随机顺序进行。在成像的腘动脉近端、中段和远端测量管壁和管腔的信噪比(SNR)、管壁与管腔的对比噪声比(CNR)、血管壁面积和管腔面积。还根据管壁可视化和管腔内伪影程度获得了图像质量评分。

结果

在近端区域,DIR 和 SPSAT 的管壁 SNR 和管壁与管腔的 CNR 均高于 MSPREP 和 T2IR。在中、远端区域,DIR 和 SPSAT 未能提供有效的血液抑制,而 MSPREP 和 T2IR 提供了足够的黑血对比,具有可比的管壁与管腔的 CNR 和图像质量。

结论

利用非流相关 T2IR 成功实现了 3D SSFP 成像技术在腘动脉壁的应用,具有有效的血液抑制和良好的血管壁可视化效果。尽管 DIR 和 SPSAT 对薄切片成像有效,但 MSPREP 和 T2IR 更适合 3D 厚切片成像。

相似文献

本文引用的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验