计算机化 Scheimpflug 密度测定术作为近视眼角膜屈光手术后角膜光学密度的测量方法。

Computerized Scheimpflug densitometry as a measure of corneal optical density after excimer laser refractive surgery in myopic eyes.

机构信息

Eye Department, University Federico II, Naples, Italy.

出版信息

J Cataract Refract Surg. 2011 Aug;37(8):1502-6. doi: 10.1016/j.jcrs.2011.03.037.

Abstract

PURPOSE

To evaluate changes in anterior corneal optical density and the refractive index after photorefractive keratectomy (PRK) using a rotating Scheimpflug system.

SETTING

Department of Ophthalmology, University Federico II, Naples, Italy.

DESIGN

Comparative case series.

METHODS

Anterior corneal optical density was evaluated with a rotating Scheimpflug system at baseline and 3 months and 12 months after PRK in eyes with a refractive error between -6.00 diopters (D) and -12.00 D (study group). A control group of unoperated eyes with the same refraction range was used to calculate corneal optical density and the Gladstone-Dale constant in unoperated eyes using the Gladstone-Dale formula. In the study group, changes in the anterior corneal optical density were evaluated over time and variations in the anterior corneal refractive index were obtained using the Gladstone-Dale constant.

RESULTS

The study group comprised 37 eyes and the control group, 200 eyes. In the study group, the mean anterior corneal optical density and refractive index, respectively, were 27.71 ± 4.39 and 1.360 ± 0.05 at baseline, 37.812 ± 12.31 and 1.491 ± 0.16 after 3 months (P<.001 compared with baseline), and 26.29 ± 4.93 and 1.341 ± 0.06 after 12 months (P=.03 compared with baseline). The mean corneal optical density in the control group was 27.71 ± 4.31 (SD), and the resultant Gladstone-Dale constant was 0.013.

CONCLUSION

An early increase and a subsequent reduction in anterior corneal optical density and the refractive index were present in myopic eyes during 1 year after PRK.

摘要

目的

使用旋转式 Scheimpflug 系统评估准分子激光角膜切削术(PRK)后前角膜光学密度和折射率的变化。

设置

意大利那不勒斯 Federico II 大学眼科系。

设计

对比病例系列。

方法

使用旋转式 Scheimpflug 系统在 PRK 术前和术后 3 个月和 12 个月评估-6.00 屈光度(D)至-12.00 D 屈光度的近视眼中的前角膜光学密度。使用 Gladstone-Dale 公式,将具有相同屈光范围的未手术眼的对照组用于计算未手术眼中的角膜光学密度和 Gladstone-Dale 常数。在研究组中,随着时间的推移评估前角膜光学密度的变化,并使用 Gladstone-Dale 常数获得前角膜折射率的变化。

结果

研究组包括 37 只眼,对照组包括 200 只眼。在研究组中,前角膜光学密度和折射率分别为 27.71 ± 4.39 和 1.360 ± 0.05 (基线)、37.812 ± 12.31 和 1.491 ± 0.16 (术后 3 个月)(与基线相比,P<.001)和 26.29 ± 4.93 和 1.341 ± 0.06 (术后 12 个月)(与基线相比,P=.03)。对照组的平均角膜光学密度为 27.71 ± 4.31(SD),得出的 Gladstone-Dale 常数为 0.013。

结论

在 PRK 后 1 年内,近视眼中出现了前角膜光学密度和折射率的早期增加和随后的减少。