Suppr超能文献

儿童的眼压与眼轴长度

Intraocular pressure and axial length in children.

作者信息

Youn D H, Yu Y S, Park I W

机构信息

Department of Ophthalmology, College of Medicine, Seoul National University, Korea.

出版信息

Korean J Ophthalmol. 1990 Jun;4(1):26-9. doi: 10.3341/kjo.1990.4.1.26.

Abstract

The intraocular pressure and the anteroposterior length of the eye are of great clinical importance for the diagnosis and management, before and after surgery, of congenital glaucoma. It is well-known that normal intraocular pressure in children is different from the normal levels in adults. We performed measurements of intraocular pressure and axial length in 141 children who had been admitted for eye problems other than glaucoma. The intraocular pressures were measured with the Perkins hand-held applanation tonometer at the beginning of general anesthesia. Simultaneously, A-scan ultra-sound measurements of the axial lengths of the eyes were made. In 10 children under the age of two years, the intraocular pressure was 11.85 +/- 1.35 mmHg. In 79 children from two to seven years, the intraocular pressure was 12.80 +/- 1.73 mmHg. In 52 children from seven to 15 years, the intraocular pressure was 13.31 +/- 1.79 mmHg. The axial lengths of the eyes in children under the age of two years, from two to seven years, and from seven to 15 years, were 21.31 +/- 0.97 mm, 22.04 +/- 0.92 mm, and 23.22 +/- 1.00 mm, respectively. These results were considered to be guidelines for measuring intraocular pressure and axial length in children suspected of having congenital glaucoma. The differences of intraocular pressures stated by other authors are due to early measurement of the intraocular pressure at the beginning of general anesthesia.

摘要

眼压和眼轴长度对于先天性青光眼手术前后的诊断和治疗具有重要的临床意义。众所周知,儿童的正常眼压与成人的正常水平不同。我们对141名因青光眼以外的眼部问题入院的儿童进行了眼压和眼轴长度测量。在全身麻醉开始时,使用珀金斯手持压平眼压计测量眼压。同时,对眼轴长度进行A超超声测量。10名两岁以下儿童的眼压为11.85±1.35 mmHg。79名2至7岁儿童的眼压为12.80±1.73 mmHg。52名7至15岁儿童的眼压为13.31±1.79 mmHg。两岁以下、2至7岁、7至15岁儿童的眼轴长度分别为21.31±0.97 mm、22.04±0.92 mm和23.22±1.00 mm。这些结果被认为是测量疑似先天性青光眼儿童眼压和眼轴长度的指导标准。其他作者所述的眼压差异是由于在全身麻醉开始时过早测量眼压所致。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验