Suppr超能文献

软 X 射线断层摄影术的图像自动配准和重建。

Automatic alignment and reconstruction of images for soft X-ray tomography.

机构信息

Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA.

出版信息

J Struct Biol. 2012 Feb;177(2):259-66. doi: 10.1016/j.jsb.2011.11.027. Epub 2011 Dec 2.

Abstract

Soft X-ray tomography (SXT) is a powerful imaging technique that generates quantitative, 3D images of the structural organization of whole cells in a near-native state. SXT is also a high-throughput imaging technique. At the National Center for X-ray Tomography (NCXT), specimen preparation and image collection for tomographic reconstruction of a whole cell require only minutes. Aligning and reconstructing the data, however, take significantly longer. Here we describe a new component of the high throughput computational pipeline used for processing data at the NCXT. We have developed a new method for automatic alignment of projection images that does not require fiducial markers or manual interaction with the software. This method has been optimized for SXT data sets, which routinely involve full rotation of the specimen. This software gives users of the NCXT SXT instrument a new capability - virtually real-time initial 3D results during an imaging experiment, which can later be further refined. The new code, Automatic Reconstruction 3D (AREC3D), is also fast, reliable, and robust. The fundamental architecture of the code is also adaptable to high performance GPU processing, which enables significant improvements in speed and fidelity.

摘要

软 X 射线断层扫描(SXT)是一种强大的成像技术,可生成近乎自然状态下整个细胞结构组织的定量、3D 图像。SXT 也是一种高通量成像技术。在国家 X 射线断层扫描中心(NCXT),整个细胞的断层重建所需的标本制备和图像采集仅需几分钟。然而,对齐和重建数据则需要更长的时间。在这里,我们描述了用于处理 NCXT 数据的高通量计算管道的一个新组件。我们开发了一种新的投影图像自动对齐方法,该方法不需要基准标记或与软件的手动交互。该方法针对 SXT 数据集进行了优化,这些数据集通常涉及标本的全旋转。该软件为 NCXT SXT 仪器的用户提供了一项新功能——在成像实验期间几乎可以实时获得初始 3D 结果,然后可以进一步进行细化。新代码 Automatic Reconstruction 3D(AREC3D)也快速、可靠且稳健。该代码的基本架构也可适应高性能 GPU 处理,从而显著提高速度和保真度。

相似文献

2
Imaging and characterizing cells using tomography.使用断层扫描对细胞进行成像和表征。
Arch Biochem Biophys. 2015 Sep 1;581:111-21. doi: 10.1016/j.abb.2015.01.011. Epub 2015 Jan 17.
3
Switchable resolution in soft x-ray tomography of single cells.单细胞软 X 射线断层扫描中的可切换分辨率。
PLoS One. 2020 Jan 24;15(1):e0227601. doi: 10.1371/journal.pone.0227601. eCollection 2020.
7
Soft X-Ray Tomography Has Evolved into a Powerful Tool for Revealing Cell Structures.软X射线断层扫描已发展成为揭示细胞结构的强大工具。
Annu Rev Anal Chem (Palo Alto Calif). 2025 May;18(1):427-446. doi: 10.1146/annurev-anchem-071124-093849. Epub 2025 Mar 3.
8
Putting molecules in their place.将分子放在它们应有的位置。
J Cell Biochem. 2014 Feb;115(2):209-16. doi: 10.1002/jcb.24658.
10
Soft X-ray tomography: virtual sculptures from cell cultures.软 X 射线断层扫描:细胞培养物的虚拟雕塑。
Curr Opin Struct Biol. 2019 Oct;58:324-332. doi: 10.1016/j.sbi.2019.06.012. Epub 2019 Sep 6.

引用本文的文献

5
8
Automated 3D cytoplasm segmentation in soft X-ray tomography.软X射线断层扫描中的自动化3D细胞质分割
iScience. 2024 Apr 29;27(6):109856. doi: 10.1016/j.isci.2024.109856. eCollection 2024 Jun 21.

本文引用的文献

1
Refinement procedure for the image alignment in high-resolution electron tomography.高分辨率电子断层扫描中图像配准的细化过程。
Ultramicroscopy. 2011 Aug-Oct;111(9-10):1512-20. doi: 10.1016/j.ultramic.2011.06.001. Epub 2011 Jun 21.
3
Fast tomographic reconstruction on multicore computers.多核计算机上的快速层析重建。
Bioinformatics. 2011 Feb 15;27(4):582-3. doi: 10.1093/bioinformatics/btq692. Epub 2010 Dec 20.
5
Alignment of cryo-electron tomography datasets.冷冻电子断层扫描数据集的比对
Methods Enzymol. 2010;482:343-67. doi: 10.1016/S0076-6879(10)82014-2.
10

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验