Feasibility of conjunctival hemodynamic measurements in rabbits: reproducibility, validity, and response to acute hypotension.

机构信息

Department of Ophthalmology, Loyola University Medical Center, Maywood, Illinois, USA.

出版信息

Microcirculation. 2012 Aug;19(6):521-9. doi: 10.1111/j.1549-8719.2012.00182.x.

Abstract

OBJECTIVE

To evaluate the feasibility of conjunctival hemodynamic measurements based on assessment of reproducibility, validity, and response to acute hypotension.

METHODS

Image sequences of the conjunctival microvasculature of rabbits were captured using a slit lamp biomicroscope under a steady-state condition, after topical administration of phenylephrine, and after intravenous administration of esmolol. Venous hemodynamic parameters (diameter, blood velocity, blood flow, and wall shear stress) were derived.

RESULTS

Conjunctival venous diameters ranged from 9 to 34 μm and blood velocities ranged from 0.08 to 0.95 mm/s. Coefficients of variation of venous diameter and blood velocity measurements were, on average, 6% and 14%, respectively. Automated and manual measurements of venous diameter and velocity were highly correlated (R = 0.97; p < 0.001; n = 16). With phenylephrine administration, diameter and velocity were reduced by 21% and 69%, respectively. Following esmolol administration, blood pressure was reduced with a concomitant decrease in velocity, followed by recovery to baseline. Venous blood velocity, flow, and WSS were correlated with blood pressure (R ≥ 0.52; p ≤ 0.01).

CONCLUSIONS

The feasibility of quantifying alterations in microvascular hemodynamics in the bulbar conjunctiva was established. The method is of potential value in evaluating microcirculatory hemodynamics related to cardiovascular function.

摘要

目的

评估基于评估重复性、有效性和对急性低血压反应的结膜血流动力学测量的可行性。

方法

使用裂隙灯生物显微镜在稳态条件下、局部给予苯肾上腺素后和静脉给予艾司洛尔后捕获兔结膜微血管的图像序列。得出静脉血流动力学参数(直径、血流速度、血流量和壁面切应力)。

结果

结膜静脉直径范围为 9 至 34μm,血流速度范围为 0.08 至 0.95mm/s。静脉直径和血流速度测量的变异系数平均分别为 6%和 14%。静脉直径和速度的自动和手动测量高度相关(R=0.97;p<0.001;n=16)。给予苯肾上腺素后,直径和速度分别减少了 21%和 69%。给予艾司洛尔后,血压降低,速度随之降低,随后恢复到基线。静脉血流速度、流量和 WSS 与血压相关(R≥0.52;p≤0.01)。

结论

在球结膜中定量评估微血管血液动力学变化的可行性已经确立。该方法在评估与心血管功能相关的微循环血液动力学方面具有潜在价值。

相似文献

7
Quantitative assessment of conjunctival microvascular circulation of the human eye.定量评估人眼结膜微血管循环。
Microvasc Res. 2010 Mar;79(2):109-13. doi: 10.1016/j.mvr.2009.12.003. Epub 2010 Jan 4.
10
Automated Assessment of Hemodynamics in the Conjunctival Microvasculature Network.结膜微血管网络血流动力学的自动评估
IEEE Trans Med Imaging. 2016 Feb;35(2):605-11. doi: 10.1109/TMI.2015.2486619. Epub 2015 Oct 6.

引用本文的文献

5
Automated Assessment of Hemodynamics in the Conjunctival Microvasculature Network.结膜微血管网络血流动力学的自动评估
IEEE Trans Med Imaging. 2016 Feb;35(2):605-11. doi: 10.1109/TMI.2015.2486619. Epub 2015 Oct 6.

本文引用的文献

1
Deaths: Leading Causes for 2011.死亡:2011年的主要死因。
Natl Vital Stat Rep. 2015 Jul 27;64(7):1-96.
4
Effects of shear stress and stretch on endothelial function.切应力和张应变对血管内皮功能的影响。
Antioxid Redox Signal. 2011 Sep 1;15(5):1389-403. doi: 10.1089/ars.2010.3361. Epub 2011 Feb 3.
6
Quantitative assessment of conjunctival microvascular circulation of the human eye.定量评估人眼结膜微血管循环。
Microvasc Res. 2010 Mar;79(2):109-13. doi: 10.1016/j.mvr.2009.12.003. Epub 2010 Jan 4.
10
Microcirculation during cardiac arrest and resuscitation.心脏骤停与复苏期间的微循环
Crit Care Med. 2006 Dec;34(12 Suppl):S454-7. doi: 10.1097/01.CCM.0000247717.81480.B2.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验