CSIRO Water for a Healthy Country Research Flagship, Waite Laboratories, Waite Rd, Urrbrae 5064, South Africa.
Water Sci Technol. 2012;65(9):1692-5. doi: 10.2166/wst.2012.069.
With the release of the Australian Guidelines for Water Recycling: Managed Aquifer Recharge (MAR), aquifers are now being included as a treatment barrier when assessing risk of recycled water systems. A MAR research site recharging urban stormwater in a confined aquifer was used in conjunction with a Quantitative Microbial Risk Assessment to assess the microbial pathogen risk in the recovered water for different end uses. The assessment involved undertaking a detailed assessment of the treatment steps and exposure controls, including the aquifer, to achieve the microbial health-based targets.