Bautista Carlos Palomino, González David Carmona, Gómez Alfredo Castillo
Hospital Universitario Quirón, Madrid, Spain.
Clin Ophthalmol. 2012;6:403-7. doi: 10.2147/OPTH.S24425. Epub 2012 Mar 21.
To evaluate the development of visual acuity, dysphotopsia phenomena, and subjective sensations in patients implanted with the Tecnis(®) ZMB00 (Advanced Medical Optics Inc, Santa Ana, CA) multifocal intraocular lens.
In a sample of 70 eyes, distance and near visual acuity, with and without correction, contrast sensitivity, and patient satisfaction, were analyzed at 15, 30, and 60 days post-surgery.
Mean uncorrected distance visual acuity (logarithm of minimum angle of resolution) at 15, 30, and 60 days was 0.194 ± 0.054, 0.119 ± 0.026, and 0.076 ± 0.014 (P < 0.0001), respectively, and with correction, 0.051 ± 0.007 vs 0.041 ± 0.004 vs 0.022 ± 0.002 (P < 0.0001), respectively. At 60 days, 94.3% of eyes could read 1.00 close-up without correction. Patient satisfaction in terms of dysphotopsia effects and visual acuity was excellent. The mean contrast sensitivity was 1.64 ± 0.10 (logarithmic units) measured with the Pelli-Robson test.
This type of multifocal intraocular lens was very effective at the distances analyzed, producing excellent objective and subjective results.
评估植入Tecnis(®) ZMB00(美国加利福尼亚州圣安娜市先进医学光学公司)多焦点人工晶状体患者的视力发育、眩光现象及主观感受。
对70只眼的样本,在术后15天、30天和60天分析其有无矫正情况下的远视力和近视力、对比敏感度及患者满意度。
术后15天、30天和60天的平均未矫正远视力(最小分辨角对数)分别为0.194±0.054、0.119±0.026和0.076±0.014(P<0.0001),矫正后分别为0.051±0.007、0.041±0.004和0.022±0.002(P<0.0001)。60天时,94.3%的眼无需矫正就能看清近视力表上的1.00。患者对眩光影响和视力的满意度很高。用贝利-罗布森测试测得的平均对比敏感度为1.64±0.10(对数单位)。
这种类型的多焦点人工晶状体在所分析的距离上非常有效,产生了出色的客观和主观结果。