Suppr超能文献

可流动树脂复合材料与三氧化矿物凝聚体相比对培养的人牙周膜细胞的细胞毒性。

Cytotoxicity of flowable resin composite on cultured human periodontal ligament cells compared with mineral trioxide aggregate.

作者信息

Trichaiyapon Vorapun, Torrungruang Kitti, Panitvisai Piyanee

机构信息

Department of Operative Dentistry, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand.

出版信息

J Investig Clin Dent. 2012 Aug;3(3):215-20. doi: 10.1111/j.2041-1626.2012.00125.x. Epub 2012 Apr 30.

Abstract

AIM

To investigate the cytotoxicity of three flowable resin composites that potentially useful as retrograde filling materials, compared with mineral trioxide aggregate (MTA).

METHODS

Ten standard cylinder discs were used for each of the tested materials: Tetric Flow, Filtex Flow, Aeliteflo, and MTA, which were prepared under aseptic conditions. Cytotoxicity of eluates from all materials after 1-4 days' immersion in culture medium and direct contact cytotoxicity were evaluated using cultured human periodontal ligament cells (PDLC). The colorimetric (3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyltetrazolium bromide) assay and scanning electron microscope of cell morphology (direct contact only) were used.

RESULTS

No eluates of set materials demonstrated cytotoxicity at any concentration or elution time. Freshly-mixed MTA was cytotoxic in direct contact, but not set MTA. Freshly-mixed Aeliteflo was also cytotoxic, as was set material up to 2 days' elution. With morphological assessment, some differences were seen among resin composites, but all changes were rated as slight using the International Standard Organization criteria.

CONCLUSIONS

Of all of the materials tested, Tetric Flow showed the least cytotoxic effects on PDLC. Further research is needed to determine the clinical usefulness of flowable composites as retrograde filling materials.

摘要

目的

研究三种可能用作倒充填材料的可流动树脂复合材料与矿物三氧化物凝聚体(MTA)相比的细胞毒性。

方法

对每种测试材料(Tetric Flow、Filtex Flow、Aeliteflo和MTA)制备10个标准圆柱盘,在无菌条件下进行。使用培养的人牙周膜细胞(PDLC)评估所有材料在培养基中浸泡1 - 4天后洗脱液的细胞毒性以及直接接触细胞毒性。采用比色法(3 - [4,5 - 二甲基噻唑 - 2 - 基] - 2,5 - 二苯基溴化四氮唑)测定法以及仅针对直接接触情况的细胞形态扫描电子显微镜观察。

结果

固化材料的洗脱液在任何浓度或洗脱时间均未表现出细胞毒性。新混合的MTA在直接接触时具有细胞毒性,但固化后的MTA没有。新混合的Aeliteflo也具有细胞毒性,其固化材料在洗脱2天内也有细胞毒性。通过形态学评估,树脂复合材料之间存在一些差异,但根据国际标准组织的标准,所有变化均被评为轻微。

结论

在所有测试材料中,Tetric Flow对PDLC的细胞毒性作用最小。需要进一步研究以确定可流动复合材料作为倒充填材料的临床实用性。