Department of Ophthalmology, University Hospital of Bern, Inselspital, Bern, Switzerland.
Front Zool. 2012 May 29;9(1):10. doi: 10.1186/1742-9994-9-10.
The aim of this study was to evaluate the visual acuity of adult zebrafish by assessing the optokinetic reflex. Using a modified commercially available optomotor device (OptoMotry®), virtual three-dimensional gratings of variable spatial frequency or contrast were presented to adult zebrafish. In a first experiment, visual acuity was evaluated by changing the spatial frequency at different angular velocities. Thereafter, contrast sensitivity was evaluated by changing the contrast level at different spatial frequencies.
At the different tested angular velocities (10, 15, 20, 25, and 30 d/s) and a contrast of 100%, visual acuity values ranged from 0.56 to 0.58 c/d. Contrast sensitivity measured at different spatial frequencies (0.011, 0.025, 0.5, 0.1, 0.2, 0.3, 0.4, 0.5 and 0.55 c/d) with an angular velocity of 10 d/s and 25 d/s revealed an inverted U-shaped contrast sensitivity curve. The highest mean contrast sensitivity (±SD) values of 20.49 ± 4.13 and 25.24 ± 8.89 were found for a spatial frequency of 0.05 c/d (angular velocity 10 d/s) and 0.1 c/d (angular velocity 25 d/s), respectively.
Visual acuity and contrast sensitivity measurements in adult zebrafish with the OptoMotry® device are feasible and reveal a remarkably higher VA compared to larval zebrafish and mice.
本研究旨在通过评估光动反应来评估成年斑马鱼的视力。使用经过改良的市售光动仪(OptoMotry®),向成年斑马鱼呈现具有不同空间频率或对比度的虚拟三维光栅。在第一个实验中,通过改变不同角速度下的空间频率来评估视力。然后,通过改变不同空间频率下的对比度水平来评估对比度敏感度。
在不同测试角速度(10、15、20、25 和 30 d/s)和 100%对比度下,视力值范围为 0.56 至 0.58 c/d。在不同空间频率(0.011、0.025、0.5、0.1、0.2、0.3、0.4、0.5 和 0.55 c/d)下测量的对比度敏感度,角速度为 10 d/s 和 25 d/s,呈现出倒置的 U 形对比度敏感度曲线。在空间频率为 0.05 c/d(角速度 10 d/s)和 0.1 c/d(角速度 25 d/s)时,对比度敏感度的平均值(±SD)分别为 20.49±4.13 和 25.24±8.89,最高。
使用 OptoMotry®设备对成年斑马鱼进行视力和对比度敏感度测量是可行的,与幼体斑马鱼和小鼠相比,视力明显更高。