Suppr超能文献

唾液和血液污染对自酸蚀粘结系统粘结强度的影响——一项体外研究。

Effect of saliva and blood contamination on the bond strength of self-etching adhesive system- An in vitro study.

作者信息

Koppolu Madhusudhana, Gogala Dorasani, Mathew Vinod B, Thangala Venugopal, Deepthi Mandava, Sasidhar Nalluru

机构信息

Department of Conservative Dentistry and Endodontics, Narayana Dental College and Hospital, Nellore, India.

出版信息

J Conserv Dent. 2012 Jul;15(3):270-3. doi: 10.4103/0972-0707.97956.

Abstract

AIM

The aims of this study were to determine the effect of saliva and blood contamination on the shear bond strength of self-etching adhesive to enamel and dentin; and, to compare the difference in bond strength due to contamination beforeand after application of the self-etch adhesive.

MATERIALS AND METHODS

40 human mandibular molars were wet ground on both buccal and lingual surfaces to prepare flat superficial enamel and dentin surfaces. They were randomly divided into two groups (n = 40) based on the substrate (enamel and dentin). Each group was further divided into five subgroups (n = 8) based on the type of contamination it was subjected to, and the step in the bonding sequence when the contamination occurred (before or after adhesive application). Fresh saliva and fresh human blood were applied either before or after the application of Xeno III(®) self-etching adhesive system (SES). Composite resin was applied as inverted, truncated cured cones that were subjected to shear bond strength test.

STATISTICAL ANALYSIS

One-way analysis of variance (ANOVA) and Tukey's Honestly Significant Difference (HSD) test were used.

RESULTS

Statistically significant reduction in the bond strength was shown after both saliva and blood contamination before and after Xeno III(®) application (P< 0.05). Bond strength is significantly reduced after contamination with blood as compared to saliva.

CONCLUSIONS

When self-etching adhesive systems are used, saliva and blood contamination significantly decrease the bond strength of the adhesive to enamel and dentin of the tooth.

摘要

目的

本研究的目的是确定唾液和血液污染对自酸蚀黏结剂与釉质和牙本质之间剪切黏结强度的影响;并比较自酸蚀黏结剂应用前后污染导致的黏结强度差异。

材料与方法

40颗人类下颌磨牙的颊面和舌面均进行湿磨,以制备平整的表层釉质和牙本质表面。根据底物(釉质和牙本质)将它们随机分为两组(n = 40)。每组根据所受污染类型以及污染发生时在黏结步骤中的阶段(黏结剂应用之前或之后)进一步分为五个亚组(n = 8)。在应用Xeno III(®)自酸蚀黏结剂系统(SES)之前或之后施加新鲜唾液和新鲜人血。复合树脂制成倒置的、截顶的固化圆锥体,进行剪切黏结强度测试。

统计分析

采用单因素方差分析(ANOVA)和Tukey真实显著差异(HSD)检验。

结果

在应用Xeno III(®)之前和之后,唾液和血液污染后黏结强度均出现统计学上的显著降低(P < 0.05)。与唾液污染相比,血液污染后黏结强度显著降低。

结论

使用自酸蚀黏结剂系统时,唾液和血液污染会显著降低黏结剂与牙齿釉质和牙本质之间的黏结强度。