Suppr超能文献

黏结系统和应用策略对降低牙本质渗透性的影响。

Effect of adhesive system and application strategy on reduction of dentin permeability.

机构信息

Department of Restorative Dentistry, Piracicaba School of Dentistry, Campinas State University, SP, Brazil.

出版信息

Braz Oral Res. 2012 Sep-Oct;26(5):397-403. doi: 10.1590/s1806-83242012005000020. Epub 2012 Aug 14.

Abstract

This study evaluated the effect of adhesive systems and application strategies on dentin hydraulic conductance (HC). The buccal enamel was removed from bovine incisors to simulate laminate cavity preparations. After removing the roots and the coronal pulp, the buccal dentin was treated with EDTA solution (0.5 M) for 5 minutes, rinsed, ultrasonicated for 12 minutes and connected to a permeability device. HC of the specimens was measured at 10 psi (n = 5). Permeability was measured before and after bonding procedures using G-Bond (GB), Clearfil Tri-S Bond (CTS), Hybrid Coat (HY), Bond Force (BF), Adper Easy Bond (AEB) Silorane (SI), Clearfil SE Bond (CSE) and Adper Scotchbond Multi-Purpose (SMP) adhesives systems, which were applied following three strategies: 1) according to the manufacturers' instructions; 2) two coats of all-in-one self-etching adhesives (GB, CTS, HY, BF, AEB) or priming step plus two coats of bonding resin for the other systems (SI, CSE and SMP); and 3) a thin layer of a flowable composite applied over one coat of all-in-one self-etching adhesives or primed surface for SI, CSE and SMP adhesives. No significant difference was observed among the application modes concerning their ability to reduce HC. None of the adhesives showed complete sealing (100%) of the bovine tooth dentin. SI exhibited lower HC than SMP, however, they were not significantly different from the other systems. The results suggest that all systems tested result in an HC reduction of more than 90%. The wet bonding technique seemed to be more sensitive for dentin sealing.

摘要

本研究评估了粘结系统和应用策略对牙本质水力传导性(HC)的影响。从牛切牙上去除颊侧釉质,模拟层状腔预备。去除根和冠髓后,用 EDTA 溶液(0.5 M)处理颊侧牙本质 5 分钟,冲洗,超声处理 12 分钟,并连接到渗透性装置。在 10 psi 下测量标本的 HC(n = 5)。在粘结程序前后使用 G-Bond(GB)、Clearfil Tri-S Bond(CTS)、Hybrid Coat(HY)、Bond Force(BF)、Adper Easy Bond(AEB)硅烷(SI)、Clearfil SE Bond(CSE)和 Adper Scotchbond Multi-Purpose(SMP)粘结系统测量渗透性,应用以下三种策略:1)根据制造商的说明;2)全酸蚀自粘结剂(GB、CTS、HY、BF、AEB)的两涂层或其他系统的预涂层加两涂层粘结树脂(SI、CSE 和 SMP);3)在全酸蚀自粘结剂或预涂层上涂一层薄薄的流动复合树脂,用于 SI、CSE 和 SMP 粘结剂。在减少 HC 的能力方面,应用模式之间没有观察到显著差异。没有一种粘结剂能完全密封(100%)牛牙本质。SI 的 HC 低于 SMP,但与其他系统无显著差异。结果表明,所有测试系统均导致 HC 降低超过 90%。湿粘结技术似乎对牙本质密封更敏感。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验