Medical Research Council Epidemiology Unit, Cambridge, UK.
Int J Behav Nutr Phys Act. 2012 Aug 31;9:103. doi: 10.1186/1479-5868-9-103.
Physical inactivity is one of the four leading risk factors for global mortality. Accurate measurement of physical activity (PA) and in particular by physical activity questionnaires (PAQs) remains a challenge. The aim of this paper is to provide an updated systematic review of the reliability and validity characteristics of existing and more recently developed PAQs and to quantitatively compare the performance between existing and newly developed PAQs.A literature search of electronic databases was performed for studies assessing reliability and validity data of PAQs using an objective criterion measurement of PA between January 1997 and December 2011. Articles meeting the inclusion criteria were screened and data were extracted to provide a systematic overview of measurement properties. Due to differences in reported outcomes and criterion methods a quantitative meta-analysis was not possible.In total, 31 studies testing 34 newly developed PAQs, and 65 studies examining 96 existing PAQs were included. Very few PAQs showed good results on both reliability and validity. Median reliability correlation coefficients were 0.62-0.71 for existing, and 0.74-0.76 for new PAQs. Median validity coefficients ranged from 0.30-0.39 for existing, and from 0.25-0.41 for new PAQs.Although the majority of PAQs appear to have acceptable reliability, the validity is moderate at best. Newly developed PAQs do not appear to perform substantially better than existing PAQs in terms of reliability and validity. Future PAQ studies should include measures of absolute validity and the error structure of the instrument.
身体活动不足是全球死亡的四个主要风险因素之一。准确测量身体活动(PA),特别是通过身体活动问卷(PAQs),仍然是一个挑战。本文的目的是提供一个更新的系统评价,评估现有的和最近开发的 PAQs 的可靠性和有效性特征,并定量比较现有的和新开发的 PAQs 之间的性能。
从 1997 年 1 月至 2011 年 12 月,对使用客观 PA 测量标准评估 PAQs 的可靠性和有效性数据的电子数据库进行了文献检索。筛选符合纳入标准的文章,并提取数据,提供测量特性的系统概述。由于报告的结果和标准方法存在差异,因此无法进行定量荟萃分析。
共有 31 项研究测试了 34 种新开发的 PAQs,65 项研究检查了 96 种现有的 PAQs。很少有 PAQs 在可靠性和有效性方面都表现出色。现有 PAQs 的可靠性相关系数中位数为 0.62-0.71,新开发的 PAQs 为 0.74-0.76。现有 PAQs 的有效性系数中位数范围为 0.30-0.39,新开发的 PAQs 为 0.25-0.41。
尽管大多数 PAQs 似乎具有可接受的可靠性,但有效性最多只是中等。就可靠性和有效性而言,新开发的 PAQs 似乎并没有比现有的 PAQs 表现得更好。未来的 PAQ 研究应包括绝对有效性和仪器误差结构的测量。
Int J Behav Nutr Phys Act. 2012-8-31
Cochrane Database Syst Rev. 2020-1-9
Cochrane Database Syst Rev. 2017-12-22
Cochrane Database Syst Rev. 2021-4-19
Health Technol Assess. 2001
JBI Database System Rev Implement Rep. 2016-4
Int J Behav Nutr Phys Act. 2017-1-31
Cochrane Database Syst Rev. 2022-6-29
Cochrane Database Syst Rev. 2022-5-23
Pediatr Rheumatol Online J. 2025-7-8
BMJ Open Sport Exerc Med. 2025-6-16
Public Health Chall. 2025-2-27
J Funct Morphol Kinesiol. 2025-5-6
J Behav Med. 2025-5-15
J Paediatr Child Health. 2025-6
J Headache Pain. 2025-2-14
J Phys Act Health. 2012-1
J Phys Act Health. 2012-1
J Phys Act Health. 2012-1
Anesthesiology. 2012-1
Eur J Epidemiol. 2011-11-17