Guangdong Province Key Laboratory of Molecular Immunology and Antibody Engineering, Antibody Engineering Center of Jinan University, Guangzhou, PR China.
Anal Chim Acta. 2012 Oct 1;745:99-105. doi: 10.1016/j.aca.2012.06.029. Epub 2012 Jul 7.
An immunochromatographic assay (ICA) using gold nanoparticles coated with monoclonal antibody (McAb) for the detection of chromium ions (Cr) in water and serum samples was developed, optimized and validated. Gold nanoparticles coated with affinity-purified monoclonal antibodies against isothiocyanobenzyl-EDTA (iEDTA)-chelated Cr(3+) were used as the detecting reagent in this completive immunoassay-based one-step test strip. The ICA was investigated to measure chromium speciation (Cr(3+) and Cr(6+) ions) in water samples. Chromium standard samples of 0-80 ng mL(-1) in water were determined by the test strips. The results showed that the visual lowest detection limit (LDL) of the test strip was 50.0 ng mL(-1). A portable colorimetric lateral flow reader was used for the quantification of Cr. The results indicated that the linear range of the ICA with colorimetric detection was 5-80 ng mL(-1). The ICA was also validated for the detection of chromium ions in serum samples. The test trips showed high stability in that they could be stored at 37°C for at least 12 weeks without significant loss of activity. The test strip also showed good selectivity for Cr detection with negligible interference from other heavy metals. Because of its low cost and short testing time (within 5 min), the test strip is especially suitable for on-site large-scale screening of Cr-polluted water samples, biomonitoring of Cr exposure, and many other field applications.
建立、优化和验证了一种基于免疫层析法的金纳米颗粒胶体检测铬离子(Cr)的方法,该方法使用了与异硫氰酸苄基-乙二胺四乙酸(iEDTA)-螯合 Cr(3+) 特异性结合的单克隆抗体(McAb)修饰的金纳米颗粒作为检测试剂。该免疫层析法用于测定水样中的铬形态(Cr(3+) 和 Cr(6+) 离子)。用该检测带测定水样品中 0-80ngmL(-1) 的铬标准样品。结果表明,检测带的目视最低检测限(LDL)为 50.0ngmL(-1)。便携式比色横向流动读数仪用于定量 Cr。结果表明,比色检测的免疫层析法的线性范围为 5-80ngmL(-1)。该免疫层析法还用于检测血清样品中的铬离子。检测带在 37°C 下至少可稳定保存 12 周,而活性无明显损失。检测带对 Cr 的检测具有良好的选择性,对其他重金属的干扰可忽略不计。由于其成本低、检测时间短(5 分钟内),该检测带特别适用于现场大规模筛选铬污染水样、铬暴露的生物监测以及许多其他现场应用。