Abstract

This study aims to compare different methods of monosodium urate crystal (MSU) detection in synovial fluid (SF) and the effect of sample storage and handling on crystal detection. A systematic literature search was performed in MEDLINE, EMBASE, the Cochrane Library and the American College of Rheumatology/European League Against Rheumatism conference abstracts of 2010 and 2011. Studies that compared a method for detecting MSU crystals in SF with polarised light microscopy (PLM) or compared various SF storage and handling factors with the detection of MSU crystals as an outcome were included. Twelve studies out of 247 identified references were included in the review. Seven studies compared different methods of MSU crystal detection in SF with PLM. Due to study heterogeneity, methodological limitations and risk of bias, no firm conclusions could be drawn from the available data. Five studies examining SF storage and handling factors were identified. A reduction in MSU crystal concentration was observed over time at room temperature that was not seen in refrigerated samples. The use of anticoagulation as a storage medium provided no benefit. Dried cytospin preparations appeared to be a suitable medium for long-term storage and delayed crystal analysis for at least 12 months. The existing data do not provide a compelling argument for the replacement of PLM as the current standard. SF sample storage and handling have an effect on MSU crystals and may impact on the reliability of analysis.

摘要

本研究旨在比较滑液(SF)中尿酸单钠晶体(MSU)检测的不同方法,以及样品储存和处理对晶体检测的影响。系统地检索了 MEDLINE、EMBASE、Cochrane 图书馆和美国风湿病学会/欧洲抗风湿病联盟 2010 年和 2011 年会议摘要中的文献。纳入的研究比较了 SF 中 MSU 晶体的检测方法与偏光显微镜(PLM),或比较了各种 SF 储存和处理因素与 MSU 晶体检测结果的关系。在 247 篇参考文献中,有 12 篇研究符合纳入标准。有 7 篇研究比较了 SF 中 MSU 晶体检测的不同方法与 PLM。由于研究的异质性、方法学的局限性和偏倚风险,现有数据无法得出确凿的结论。共确定了 5 项研究,探讨了 SF 储存和处理因素。室温下 MSU 晶体浓度随时间降低,但冷藏样本中未见此现象。抗凝剂作为储存介质没有提供益处。干燥的细胞旋片制备似乎是一种适合长期储存和延迟晶体分析至少 12 个月的方法。现有数据并没有为取代 PLM 作为当前标准提供有力依据。SF 样本的储存和处理对 MSU 晶体有影响,可能会影响分析的可靠性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验