Suppr超能文献

乳房重建的主观评估与客观评估。

Subjective versus objective assessment of breast reconstruction.

机构信息

Biotechnology and Craniofacial Sciences Research Group, Glasgow University, UK.

出版信息

J Plast Reconstr Aesthet Surg. 2013 May;66(5):634-9. doi: 10.1016/j.bjps.2013.01.006. Epub 2013 Feb 9.

Abstract

BACKGROUND

To date breast assessment has been conducted mainly subjectively. However lately validated objective three-dimensional (3D) imaging was developed. The study aimed to assess breast reconstruction subjectively and objectively and conduct a comparison.

METHODS

In forty-four patients after immediate unilateral breast reconstruction with solely the extended latissimus dorsi flap the breast was captured by validated 3D imaging method and standardized 2D photography. Breast symmetry was subjectively evaluated by six experts who applied the Harris score giving a mark of 1-4 for a poor to excellent result. An error study was conducted by examination of the intra and inter-observer agreement and agreement on controls. By Procrustes analysis an objective asymmetry score was obtained and compared to the subjective assessment.

RESULTS

The subjective assessment showed that the inter-observer agreement was good or substantial (p-value: <0.0001). There was moderate agreement on the controls (p-value: <0.0001) and fair (p-values: 0.159, 0.134, 0.099) to substantial (p-value: 0.005) intra-observer agreement. The objective assessment revealed that the reconstructed breast showed a significantly smaller volume compared to the opposite side and that the average asymmetry score was 0.052, ranging from 0.019 to 0.136. When comparing the subjective and objective method the relationship between the two scores was highly significant.

CONCLUSION

Subjective breast assessment lacked accuracy and reproducibility. This was the first error study of subjective breast assessment versus an objective validated 3D imaging method based on true 3D parameters. The substantial agreement between established subjective breast assessment and new validated objective method supported the value of the later and we expect its future role to expand.

摘要

背景

迄今为止,乳房评估主要是主观进行的。然而,最近已经开发出了经过验证的客观三维(3D)成像技术。本研究旨在对乳房重建进行主观和客观评估,并进行比较。

方法

在 44 例即刻单侧乳房重建中,仅使用扩展的 Latissimus dorsi 皮瓣,通过经过验证的 3D 成像方法和标准化的 2D 摄影对乳房进行了捕获。六位专家应用 Harris 评分对乳房对称性进行了主观评估,评分为 1-4 分,分数越低表示结果越差。通过检查内部和外部观察者之间的一致性以及对照的一致性,进行了误差研究。通过 Procrustes 分析获得了客观的不对称评分,并与主观评估进行了比较。

结果

主观评估表明,观察者之间的一致性良好或很高(p 值:<0.0001)。对对照组的一致性中等(p 值:<0.0001),而观察者内部的一致性则为公平(p 值:0.159、0.134、0.099)到高(p 值:0.005)。客观评估显示,与对侧相比,重建后的乳房体积明显较小,平均不对称评分 0.052,范围为 0.019 至 0.136。当比较主观和客观方法时,两种评分之间的关系高度显著。

结论

主观乳房评估缺乏准确性和可重复性。这是首次针对基于真实 3D 参数的主观乳房评估与客观验证的 3D 成像方法的误差研究。既定的主观乳房评估与新的验证的客观方法之间的实质性一致性支持了后者的价值,我们预计它的未来作用将扩大。