Kanellopoulos A John, Asimellis George
Laservision.gr Institute, Athens, Greece ; NYU Medical School, NY, USA.
Clin Ophthalmol. 2013;7:261-9. doi: 10.2147/OPTH.S40454. Epub 2013 Feb 21.
The evaluation of the safety, efficacy, and long-term stability of LASIK procedures utilizing novel platform comprising a femtosecond and excimer laser and multiple networked diagnostics.
Private clinical ophthalmology practice.
In consecutive cases of myopic LASIK procedure with a novel refractive platform (FS200 Femtosecond and EX500 Excimer Laser), 190 eyes (from 109 different patients) were evaluated pre- and postoperatively for the following parameters: refractive error, best corrected distance visual acuity, uncorrected distance visual acuity, topography (Placido-disc based) and tomography (Scheimpflug-image based), wavefront analysis, pupillometry, and contrast sensitivity. Follow-up visits were conducted for at least 12 months.
The change from pre- to postoperative mean refractive error was from -5.29 ± 2.39 diopters (D) (range -8.0 to -0.50 D) to -0.27 ± 0.09 D at the 3-month visit, -0.27 ± 0.10 D at the 6-month visit, and -0.39 ± 0.08 D at the 1-year visit. The change from pre- to postoperative refractive astigmatism was -1.07 ± 0.91 D (range -4.25 to 0 D) to -0.14 ± 0.04 D at 3 months, -0.15 ± 0.04 at 6 months, and -0.16 ± 0.04 at the 1-year visit. The proportion of the eyes with postoperative astigmatism within 0.5 D ranged between 95.6% and 99%. The proportion of eyes achieving uncorrected distance visual acuity of 1.0 (decimal) was 93.0%.
The myopic LASIK clinical results with the FS200 Femtosecond Laser and EX500 Excimer Laser showed outstanding efficacy, great safety, and long-term stability.
评估使用包含飞秒激光、准分子激光及多种联网诊断设备的新型平台进行准分子原位角膜磨镶术(LASIK)的安全性、有效性和长期稳定性。
私立临床眼科诊所。
对于采用新型屈光平台(FS200飞秒激光和EX500准分子激光)进行近视LASIK手术的连续病例,对190只眼(来自109位不同患者)在术前和术后评估以下参数:屈光不正、最佳矫正远视力、未矫正远视力、地形图(基于普拉西多盘)和断层扫描(基于Scheimpflug图像)、波前分析、瞳孔测量和对比敏感度。随访至少12个月。
术前至术后平均屈光不正的变化为:术前为-5.29±2.39屈光度(D)(范围-8.0至-0.50 D),3个月随访时为-0.27±0.09 D,6个月随访时为-0.27±0.10 D,1年随访时为-0.39±0.08 D。术前至术后屈光性散光的变化为:术前为-1.07±0.91 D(范围-4.25至0 D),3个月时为-0.14±0.04 D,6个月时为-0.15±0.04 D,1年时为-0.16±0.04 D。术后散光在0.5 D以内的眼的比例在95.6%至99%之间。未矫正远视力达到1.0(小数)的眼的比例为93.0%。
使用FS200飞秒激光和EX500准分子激光进行近视LASIK手术的临床结果显示出卓越的疗效、高度的安全性和长期稳定性。