社区居住的绝经后妇女的血清和唾液中多重细胞因子检测的性能。

Performance of multiplex cytokine assays in serum and saliva among community-dwelling postmenopausal women.

机构信息

Department of Biotechnical and Clinical Laboratory Sciences, University at Buffalo, Buffalo, New York, USA.

出版信息

PLoS One. 2013;8(4):e59498. doi: 10.1371/journal.pone.0059498. Epub 2013 Apr 5.

Abstract

Multiplexing arrays increase the throughput and decrease sample requirements for studies employing multiple biomarkers. The goal of this project was to examine the performance of Multiplex arrays for measuring multiple protein biomarkers in saliva and serum. Specimens from the OsteoPerio ancillary study of the Women's Health Initiative Observational Study were used. Participants required the presence of at least 6 teeth and were excluded based on active cancer and certain bone issues but were not selected on any specific condition. Quality control (QC) samples were created from pooled serum and saliva. Twenty protein markers were measured on five multiplexing array panels. Sample pretreatment conditions were optimized for each panel. Recovery, lower limit of quantification (LLOQ) and imprecision were determined for each analyte. Statistical adjustment at the plate level was used to reduce imprecision estimates and increase the number of usable observations. Sample pre-treatment improved recovery estimates for many analytes. The LLOQ for each analyte agreed with manufacturer specifications except for MMP-1 and MMP-2 which were significantly higher than reported. Following batch adjustment, 17 of 20 biomarkers in serum and 9 of 20 biomarkers in saliva demonstrated acceptable precision, defined as <20% coefficient of variation (<25% at LLOQ). The percentage of cohort samples having levels within the reportable range for each analyte varied from 10% to 100%. The ratio of levels in saliva to serum varied from 1∶100 to 28∶1. Correlations between saliva and serum were of moderate positive magnitude and significant for CRP, MMP-2, insulin, adiponectin, GM-CSF and IL-5. Multiplex arrays exhibit high levels of analytical imprecision, particularly at the batch level. Careful sample pre-treatment can enhance recovery and reduce imprecision. Following statistical adjustments to reduce batch effects, we identified biomarkers that are of acceptable quality in serum and to a lesser degree in saliva using Multiplex arrays.

摘要

多重分析可增加通量并减少对多个生物标志物研究的样本需求。本项目的目的是研究多重分析用于测量唾液和血清中多种蛋白质生物标志物的性能。使用了女性健康倡议观察研究的 OsteoPerio 辅助研究的标本。参与者需要至少有 6 颗牙齿,并且根据活跃的癌症和某些骨骼问题被排除在外,但没有选择任何特定的条件。使用来自混合血清和唾液的质量控制 (QC) 样本。在五个多重分析面板上测量了 20 个蛋白质标记物。针对每个面板优化了样品预处理条件。确定了每个分析物的回收率、定量下限 (LLOQ) 和不精密度。在板水平进行统计调整,以降低不精密度估计值并增加可用于观察的数量。许多分析物的样品预处理改善了回收率估计值。每个分析物的LLOQ 均符合制造商的规格,除 MMP-1 和 MMP-2 外,这两个分析物的 LLOQ 明显高于报告值。在批处理调整后,血清中的 20 种生物标志物中有 17 种和唾液中的 20 种生物标志物中有 9 种具有可接受的精密度,定义为<20%的变异系数(<25%在 LLOQ)。每个分析物的报告范围内的队列样本百分比从 10%到 100%不等。唾液与血清之间的水平比值从 1∶100 到 28∶1 不等。CRP、MMP-2、胰岛素、脂联素、GM-CSF 和 IL-5 的唾液与血清之间的相关性呈中度正相关且具有统计学意义。多重分析显示出高水平的分析不精密度,特别是在批次水平。仔细的样品预处理可以提高回收率并降低不精密度。在进行统计调整以减少批次效应后,我们确定了使用多重分析在血清中具有可接受质量且在一定程度上在唾液中具有可接受质量的生物标志物。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/4dca/3618114/d954eb2d3e10/pone.0059498.g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验