文献检索文档翻译深度研究
Suppr Zotero 插件Zotero 插件
邀请有礼套餐&价格历史记录

新学期,新优惠

限时优惠:9月1日-9月22日

30天高级会员仅需29元

1天体验卡首发特惠仅需5.99元

了解详情
不再提醒
插件&应用
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
高级版
套餐订阅购买积分包
AI 工具
文献检索文档翻译深度研究
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2025

Experimental and simulation studies on the behavior of signal harmonics in magnetic particle imaging.

作者信息

Murase Kenya, Konishi Takashi, Takeuchi Yuki, Takata Hiroshige, Saito Shigeyoshi

机构信息

Division of Medical Technology and Science, Department of Medical Physics and Engineering, Faculty of Health Science, Graduate School of Medicine, Osaka University, 1-7 Yamadaoka, Suita, Osaka 565-0871, Japan.

出版信息

Radiol Phys Technol. 2013 Jul;6(2):399-414. doi: 10.1007/s12194-013-0213-6. Epub 2013 Apr 16.


DOI:10.1007/s12194-013-0213-6
PMID:23589334
Abstract

Our purpose in this study was to investigate the behavior of signal harmonics in magnetic particle imaging (MPI) by experimental and simulation studies. In the experimental studies, we made an apparatus for MPI in which both a drive magnetic field (DMF) and a selection magnetic field (SMF) were generated with a Maxwell coil pair. The MPI signals from magnetic nanoparticles (MNPs) were detected with a solenoid coil. The odd- and even-numbered harmonics were calculated by Fourier transformation with or without background subtraction. The particle size of the MNPs was measured by transmission electron microscopy (TEM), dynamic light-scattering, and X-ray diffraction methods. In the simulation studies, the magnetization and particle size distribution of MNPs were assumed to obey the Langevin theory of paramagnetism and a log-normal distribution, respectively. The odd- and even-numbered harmonics were calculated by Fourier transformation under various conditions of DMF and SMF and for three different particle sizes. The behavior of the harmonics largely depended on the size of the MNPs. When we used the particle size obtained from the TEM image, the simulation results were most similar to the experimental results. The similarity between the experimental and simulation results for the even-numbered harmonics was better than that for the odd-numbered harmonics. This was considered to be due to the fact that the odd-numbered harmonics were more sensitive to background subtraction than were the even-numbered harmonics. This study will be useful for a better understanding, optimization, and development of MPI and for designing MNPs appropriate for MPI.

摘要

相似文献

[1]
Experimental and simulation studies on the behavior of signal harmonics in magnetic particle imaging.

Radiol Phys Technol. 2013-7

[2]
Characterization of magnetic nanoparticle systems with respect to their magnetic particle imaging performance.

Biomed Tech (Berl). 2013-12

[3]
Magnetic particle imaging: introduction to imaging and hardware realization.

Z Med Phys. 2012-8-19

[4]
Optimizing magnetite nanoparticles for mass sensitivity in magnetic particle imaging.

Med Phys. 2011-3

[5]
Frequency distribution of the nanoparticle magnetization in the presence of a static as well as a harmonic magnetic field.

Med Phys. 2008-5

[6]
Magnetic Nanoparticles in Macrophages and Cancer Cells Exhibit Different Signal Behavior on Magnetic Particle Imaging.

J Nanosci Nanotechnol. 2019-11-1

[7]
On the formulation of the image reconstruction problem in magnetic particle imaging.

Biomed Tech (Berl). 2013-12

[8]
Thermoacoustic tomography from magnetic nanoparticles by single-pulse magnetic field.

Med Phys. 2022-1

[9]
Cellular uptake of magnetic nanoparticles imaged and quantified by magnetic particle imaging.

Sci Rep. 2020-2-5

[10]
Simulational validation of color magnetic particle imaging (cMPI).

Phys Med Biol. 2014-11-7

引用本文的文献

[1]
Applications of Magnetic Particle Imaging in Biomedicine: Advancements and Prospects.

Front Physiol. 2022-7-1

[2]
The Applications of Magnetic Particle Imaging: From Cell to Body.

Diagnostics (Basel). 2020-10-9

[3]
Dynamic magnetic characterization and magnetic particle imaging enhancement of magnetic-gold core-shell nanoparticles.

Nanoscale. 2019-3-28

[4]
Design and validation of magnetic particle spectrometer for characterization of magnetic nanoparticle relaxation dynamics.

AIP Adv. 2017-3-2

[5]
Design of superparamagnetic nanoparticles for magnetic particle imaging (MPI).

Int J Mol Sci. 2013-9-11

本文引用的文献

[1]
Tracer design for magnetic particle imaging (invited).

J Appl Phys. 2012-4-1

[2]
Development of a standard method for nanoparticle sizing by using the angular dependence of dynamic light scattering.

Anal Sci. 2011

[3]
Simulation and experimental studies on magnetic hyperthermia with use of superparamagnetic iron oxide nanoparticles.

Radiol Phys Technol. 2011-7

[4]
Substrate dependent structural and magnetic properties of pulsed laser deposited Fe3O4 thin films.

J Nanosci Nanotechnol. 2010-12

[5]
Detecting the magnetic response of iron oxide capped organosilane nanostructures using magnetic sample modulation and atomic force microscopy.

Anal Chem. 2009-6-15

[6]
Signal encoding in magnetic particle imaging: properties of the system function.

BMC Med Imaging. 2009-4-1

[7]
Frequency distribution of the nanoparticle magnetization in the presence of a static as well as a harmonic magnetic field.

Med Phys. 2008-5

[8]
Magnetism.

Science. 1964-2-7

[9]
Tomographic imaging using the nonlinear response of magnetic particles.

Nature. 2005-6-30

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

推荐工具

医学文档翻译智能文献检索