Suppr超能文献

新旧两代 ActiGraph 加速度计与正常滤波器和低频扩展的比较。

Comparison of older and newer generations of ActiGraph accelerometers with the normal filter and the low frequency extension.

机构信息

Department of Psychology, San Diego State University, San Diego, CA, USA.

出版信息

Int J Behav Nutr Phys Act. 2013 Apr 25;10:51. doi: 10.1186/1479-5868-10-51.

Abstract

BACKGROUND

Many studies used the older ActiGraph (7164) for physical activity measurement, but this model has been replaced with newer ones (e.g., GT3X+). The assumption that new generation models are more accurate has been questioned, especially for measuring lower intensity levels. The low-frequency extension (LFE) increases the low-intensity sensitivity of newer models, but its comparability with older models is unknown. This study compared step counts and physical activity collected with the 7164 and GT3X + using the Normal Filter and the LFE (GT3X+N and GT3X+LFE, respectively).

FINDINGS

Twenty-five adults wore 2 accelerometer models simultaneously for 3 days and were instructed to engage in typical behaviors. Average daily step counts and minutes per day in nonwear, sedentary, light, moderate, and vigorous activity were calculated. Repeated measures ANOVAs with post-hoc pairwise comparisons were used to compare mean values. Means for the GT3X+N and 7164 were significantly different in 4 of the 6 categories (p<.05). The GT3X+N showed 2041 fewer steps per day and more sedentary, less light, and less moderate than the 7164 (+25.6, -31.2, -2.9 mins/day, respectively). The GT3X+LFE showed non-significant differences in 5 of 6 categories but recorded significantly more steps (+3597 steps/day; p<.001) than the 7164.

CONCLUSION

Studies using the newer ActiGraphs should employ the LFE for greater sensitivity to lower intensity activity and more comparable activity results with studies using the older models. Newer generation ActiGraphs do not produce comparable step counts to the older generation devices with the Normal filter or the LFE.

摘要

背景

许多研究使用较旧的 ActiGraph(7164)来测量身体活动,但该模型已被较新的型号(例如 GT3X+)所取代。人们认为新一代模型更准确,但对于测量较低强度水平的活动,这种假设受到了质疑。低频扩展(LFE)提高了较新模型对低强度的敏感度,但它与旧模型的可比性尚不清楚。本研究比较了使用普通滤波器和低频扩展(分别为 GT3X+N 和 GT3X+LFE)的 7164 和 GT3X+ 收集的步数和身体活动。

发现

25 名成年人同时佩戴 2 个加速度计模型 3 天,并被指示进行典型行为。计算平均每日步数和非佩戴、久坐、轻度、中度和剧烈活动的每日分钟数。使用重复测量方差分析和事后两两比较比较平均值。GT3X+N 和 7164 的平均值在 6 个类别中的 4 个(p<.05)有显著差异。GT3X+N 每天的步数比 7164 少 2041 步,且更多的时间处于久坐状态,更少的时间处于轻度和中度活动状态(分别为+25.6、-31.2、-2.9 分钟/天)。GT3X+LFE 在 6 个类别中的 5 个类别中差异不显著,但记录的步数比 7164 多(+3597 步/天;p<.001)。

结论

使用较新的 ActiGraph 进行的研究应使用 LFE 以提高对较低强度活动的敏感度,并使使用较旧模型的研究获得更具可比性的活动结果。新一代的 ActiGraph 不会像普通滤波器或 LFE 那样产生与旧一代设备可比的步数。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/9d29/3641979/522ebc2c82fd/1479-5868-10-51-1.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验